| - Presented paper deals with description of methodology and concept of patient's head position monitoring after vitreoretinal surgery. Keeping the head in an optimum position during the postoperative recovery period is crucial for the whole recovery process to proceed well. A device helping the patient in maintaining proper head position is described. Utilization of modern MEMS accelerometer and a microcontroller is discussed. A compact battery-powered device design is intended to be a part of a complex telemetric system for postoperative head position monitoring.
- Presented paper deals with description of methodology and concept of patient's head position monitoring after vitreoretinal surgery. Keeping the head in an optimum position during the postoperative recovery period is crucial for the whole recovery process to proceed well. A device helping the patient in maintaining proper head position is described. Utilization of modern MEMS accelerometer and a microcontroller is discussed. A compact battery-powered device design is intended to be a part of a complex telemetric system for postoperative head position monitoring. (en)
- Článek se zabývá popisem metodiky monitorování hlavy pacienta po vitreoretinálním chirurgickém zákroku a následně samotným návrhem zařízení určeného k tomuto účelu. Pro optimální průběh rekonvalescence v pooperačním období je mimořádně důležité udržovat hlavu pacienta v optimální poloze. Bylo vyvinuto elektronické zařízení napomáhající pacientu udržovat správnou polohu hlavy. Byl využit moderní MEMS akcelerometr a mikrokontroler typu RISC. Kompaktní, bateriově napájený přístroj je schopen pacienta upozornit v případě špatného držení hlavy. Zařízení bude částí koplexního telemetrického sytému. (cs)
|
Title
| - Postoperative Monitoring of Head Position
- Monitorovaní hlavy pacienta v pooperačním období (cs)
- Postoperative Monitoring of Head Position (en)
|
skos:prefLabel
| - Postoperative Monitoring of Head Position
- Monitorovaní hlavy pacienta v pooperačním období (cs)
- Postoperative Monitoring of Head Position (en)
|
skos:notation
| - RIV/00216305:26220/07:PU68901!RIV08-MSM-26220___
|
http://linked.open.../vavai/riv/strany
| |
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/00216305:26220/07:PU68901
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - Head, position, monitoring, MEMS, accelerometer, microcontroller (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...v/mistoKonaniAkce
| - Dept. of Applied Electronics and Telecommunicati
|
http://linked.open...i/riv/mistoVydani
| |
http://linked.open...i/riv/nazevZdroje
| - Applied Electronics 2007, Sborník referátů mezinárodní konference
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...iv/tvurceVysledku
| - Čížek, Martin
- Dlouhý, Jiří
- Rozman, Jiří
|
http://linked.open...vavai/riv/typAkce
| |
http://linked.open.../riv/zahajeniAkce
| |
number of pages
| |
http://purl.org/ne...btex#hasPublisher
| - Západočeská univerzita v Plzni
|
https://schema.org/isbn
| |
http://localhost/t...ganizacniJednotka
| |
is http://linked.open...avai/riv/vysledek
of | |