About: Checking the quality of gradient magnetic fields     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Imaging techniques based on the principle of nuclear magnetic resonance (MRI) can be used in the study of molecular transport phenomena in biological systems such as self-diffusion processes. The precision of determining the diffusion constants depends on generating the gradient pulse with high precision. For the purpose of determining the characteristics of time behaviour of gradient pulses a simple measuring method was developed and experimentally tested on a 4.7 T tomograph. The method is based on the principle of measuring the instantaneous frequency of MR signal in the presence of gradient pulse after the excitation of a thin defined layer of the examined specimen placed outside the gradient field centre. Using the above method, errors were found in the amplitude and time integral of generated gradient fields and in determining the diffusion constants for biological tissues.
  • Imaging techniques based on the principle of nuclear magnetic resonance (MRI) can be used in the study of molecular transport phenomena in biological systems such as self-diffusion processes. The precision of determining the diffusion constants depends on generating the gradient pulse with high precision. For the purpose of determining the characteristics of time behaviour of gradient pulses a simple measuring method was developed and experimentally tested on a 4.7 T tomograph. The method is based on the principle of measuring the instantaneous frequency of MR signal in the presence of gradient pulse after the excitation of a thin defined layer of the examined specimen placed outside the gradient field centre. Using the above method, errors were found in the amplitude and time integral of generated gradient fields and in determining the diffusion constants for biological tissues. (en)
  • Zobrazovací techniky pracující na bázi magnetické resonance mohou být využity pro studium transportních dějů v biologických systémech pomocí difúzních procesů. Přesné určení difúzních konstant závisí na přesnosti gradientních pulsů. Pro určení časových charakteristik gradientních pulsů byla vyvinuta a experimentálně ověřena měřicí metoda. Ta je založena na měření okamžité frekvence MR signálu za přítomnosti gradientního pulsu po excitaci tenké vrstvy vyšetřovaného vzorku v poloze mimo střed gradientu. Touto metodou byly zjištěny chyby v amplitudě a integrálu gradieního pulsu a při stanovení difúzního koeficientu v biologických tkáních. (cs)
Title
  • Checking the quality of gradient magnetic fields
  • Checking the quality of gradient magnetic fields (en)
  • Kontrola kvality gradientních magnetických polí (cs)
skos:prefLabel
  • Checking the quality of gradient magnetic fields
  • Checking the quality of gradient magnetic fields (en)
  • Kontrola kvality gradientních magnetických polí (cs)
skos:notation
  • RIV/00216305:26220/06:PU61629!RIV07-MSM-26220___
http://linked.open.../vavai/riv/strany
  • 207-210
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(AV0Z20650511), Z(MSM0021630513)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 468494
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26220/06:PU61629
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • gradient magnetic field, magnetic resonance (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [02F024A903EA]
http://linked.open...v/mistoKonaniAkce
  • Gliwice-Ustroń, Polsko
http://linked.open...i/riv/mistoVydani
  • Gliwice-Ustron
http://linked.open...i/riv/nazevZdroje
  • INTERNATIONAL CONFERENCE ON FUNDAMENTALS OF ELECTROTECHNICS AND CIRCUIT THEORY 2006
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Bartušek, Karel
  • Gescheidtová, Eva
  • Kubásek, Radek
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
http://linked.open...n/vavai/riv/zamer
number of pages
http://purl.org/ne...btex#hasPublisher
  • Silesian University of Technology
https://schema.org/isbn
  • 83-85940-28-6
http://localhost/t...ganizacniJednotka
  • 26220
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software