About: Comparison of Wave-Equation Based Versus Measurement-Processing Transducer Calibration for Ultrasonic Transmission Tomography     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The contribution deals with the first step in using proper wave-equation based ultrasound propagation model in image reconstruction from the ultrasonic computed tomography data. Particularly, it compares the transducer calibration results obtained via direct measurement of the empty image field and consequential data processing based on a simple direct-propagation model with the simulation results obtained via solving the single-frequency wave equation under proper border conditions reflecting the realiistic measurement geometry. The results show a reasonable qualitative agreement when a certain degree of phase-shifted coupling from the transmitting transducer elements to the neighbouring elements of the transducer field is admitted.
  • The contribution deals with the first step in using proper wave-equation based ultrasound propagation model in image reconstruction from the ultrasonic computed tomography data. Particularly, it compares the transducer calibration results obtained via direct measurement of the empty image field and consequential data processing based on a simple direct-propagation model with the simulation results obtained via solving the single-frequency wave equation under proper border conditions reflecting the realiistic measurement geometry. The results show a reasonable qualitative agreement when a certain degree of phase-shifted coupling from the transmitting transducer elements to the neighbouring elements of the transducer field is admitted. (en)
  • The contribution deals with the first step in using proper wave-equation based ultrasound propagation model in image reconstruction from the ultrasonic computed tomography data. Particularly, it compares the transducer calibration results obtained via direct measurement of the empty image field and consequential data processing based on a simple direct-propagation model with the simulation results obtained via solving the single-frequency wave equation under proper border conditions reflecting the realiistic measurement geometry. The results show a reasonable qualitative agreement when a certain degree of phase-shifted coupling from the transmitting transducer elements to the neighbouring elements of the transducer field is admitted. (cs)
Title
  • Comparison of Wave-Equation Based Versus Measurement-Processing Transducer Calibration for Ultrasonic Transmission Tomography
  • Comparison of Wave-Equation Based Versus Measurement-Processing Transducer Calibration for Ultrasonic Transmission Tomography (en)
  • Comparison of Wave-Equation Based Versus Measurement-Processing Transducer Calibration for Ultrasonic Transmission Tomography (cs)
skos:prefLabel
  • Comparison of Wave-Equation Based Versus Measurement-Processing Transducer Calibration for Ultrasonic Transmission Tomography
  • Comparison of Wave-Equation Based Versus Measurement-Processing Transducer Calibration for Ultrasonic Transmission Tomography (en)
  • Comparison of Wave-Equation Based Versus Measurement-Processing Transducer Calibration for Ultrasonic Transmission Tomography (cs)
skos:notation
  • RIV/00216305:26220/06:PU61045!RIV06-MSM-26220___
http://linked.open.../vavai/riv/strany
  • 2754-2757
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(1M0572)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 469340
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26220/06:PU61045
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Ultrasonic, Wave-Equation (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [73AC49D28BD9]
http://linked.open...v/mistoKonaniAkce
  • New York
http://linked.open...i/riv/mistoVydani
  • New York (USA)
http://linked.open...i/riv/nazevZdroje
  • Proceedings of 28th Annual International Conference IEEE EMBS
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Jan, Jiří
  • Jiřík, Radovan
  • Kolář, Radim
  • Hemzal, Dušan
  • Filipík, Adam
  • Začal, Jiří
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • Neuveden
https://schema.org/isbn
  • 1-4244-0033-3
http://localhost/t...ganizacniJednotka
  • 26220
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software