Attributes | Values |
---|
rdf:type
| |
Description
| - Fast detection of pesticide toxicity in the field conditions is very important in many aspects (longtime influence of low concentrations on man s health, pesticide storage, price of one test etc.). The pesticide concentration measurements are performed on a biosensor with acetylcholinesterase (AChE). The AChE is a very sensitive compound. The measurement uses principle of an artificial synapse (AS) and inhibition of an enzyme Acetylcholinesterase (AChE). The AS is a very effective detector of the pesticcide toxicity. Therefore properties of the sensor have to be measured without AChE at first. This process is called input control of the sensor. The reproducibility of electrochemical detector is studied first using hydrogen peroxide and second ferri-ferrokyanide redox couple. The parameters of electrochemical detector itself were evaluated statistically.
- Fast detection of pesticide toxicity in the field conditions is very important in many aspects (longtime influence of low concentrations on man s health, pesticide storage, price of one test etc.). The pesticide concentration measurements are performed on a biosensor with acetylcholinesterase (AChE). The AChE is a very sensitive compound. The measurement uses principle of an artificial synapse (AS) and inhibition of an enzyme Acetylcholinesterase (AChE). The AS is a very effective detector of the pesticcide toxicity. Therefore properties of the sensor have to be measured without AChE at first. This process is called input control of the sensor. The reproducibility of electrochemical detector is studied first using hydrogen peroxide and second ferri-ferrokyanide redox couple. The parameters of electrochemical detector itself were evaluated statistically. (en)
|
Title
| - INPUT CONTROL OF SENSOR PARAMETERS AND REPRODUCIBILITY OF SENSOR MEASUREMENT
- INPUT CONTROL OF SENSOR PARAMETERS AND REPRODUCIBILITY OF SENSOR MEASUREMENT (en)
|
skos:prefLabel
| - INPUT CONTROL OF SENSOR PARAMETERS AND REPRODUCIBILITY OF SENSOR MEASUREMENT
- INPUT CONTROL OF SENSOR PARAMETERS AND REPRODUCIBILITY OF SENSOR MEASUREMENT (en)
|
skos:notation
| - RIV/00216305:26220/03:PU37157!RIV/2004/MSM/262204/N
|
http://linked.open.../vavai/riv/strany
| |
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/00216305:26220/03:PU37157
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - sensor, biosensor, input control, hydrogen peroxide (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...v/mistoKonaniAkce
| |
http://linked.open...i/riv/mistoVydani
| |
http://linked.open...i/riv/nazevZdroje
| - XVII IMEKO WORLD CONGRESS
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...ocetUcastnikuAkce
| |
http://linked.open...nichUcastnikuAkce
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...iv/tvurceVysledku
| - Fujcik, Lukáš
- Háze, Jiří
- Vrba, Radimír
- Krejčí, Jan
- Sajdl, Ondřej
- Skočdopole, Michal
|
http://linked.open...vavai/riv/typAkce
| |
http://linked.open.../riv/zahajeniAkce
| |
http://linked.open...n/vavai/riv/zamer
| |
number of pages
| |
http://purl.org/ne...btex#hasPublisher
| |
https://schema.org/isbn
| |
http://localhost/t...ganizacniJednotka
| |