About: Iterative Method of Measurements for Chemical sensors     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The paper contributes to the field of precise electrolytic conductivity measurements with planar sensors. This novel measuring method was suggested for measurement with IDEs thick-film electrodes. Correction characteristics over a wide range of a specific conductivities were determined from an interface impedance characterisation of the thick-film IDEs. The cell constant strongly depends on the frequency and conductivity of solutions. A local minimum of the imaginary part of the interface impedance is uused for corrections to get linear responses. In this minimum a ridge frequency and cell constant were determined for each measured conductivity. An iteration mode of measurements was suggested to exactly measure the conductivity in the ridge frequency in order to achieve a highly accurate response. An implementation of this method as a microcontroller application can used to build-up microsystem for precise conductivity measurements in concentration ranges from 10-6 to 1 M without cell replacement.
  • The paper contributes to the field of precise electrolytic conductivity measurements with planar sensors. This novel measuring method was suggested for measurement with IDEs thick-film electrodes. Correction characteristics over a wide range of a specific conductivities were determined from an interface impedance characterisation of the thick-film IDEs. The cell constant strongly depends on the frequency and conductivity of solutions. A local minimum of the imaginary part of the interface impedance is uused for corrections to get linear responses. In this minimum a ridge frequency and cell constant were determined for each measured conductivity. An iteration mode of measurements was suggested to exactly measure the conductivity in the ridge frequency in order to achieve a highly accurate response. An implementation of this method as a microcontroller application can used to build-up microsystem for precise conductivity measurements in concentration ranges from 10-6 to 1 M without cell replacement. (en)
  • The paper contributes to the field of precise electrolytic conductivity measurements with planar sensors. This novel measuring method was suggested for measurement with IDEs thick-film electrodes. Correction characteristics over a wide range of a specific conductivities were determined from an interface impedance characterisation of the thick-film IDEs. The cell constant strongly depends on the frequency and conductivity of solutions. A local minimum of the imaginary part of the interface impedance is uused for corrections to get linear responses. In this minimum a ridge frequency and cell constant were determined for each measured conductivity. An iteration mode of measurements was suggested to exactly measure the conductivity in the ridge frequency in order to achieve a highly accurate response. An implementation of this method as a microcontroller application can used to build-up microsystem for precise conductivity measurements in concentration ranges from 10-6 to 1 M without cell replacement. (cs)
Title
  • Iterative Method of Measurements for Chemical sensors
  • Iterative Method of Measurements for Chemical sensors (en)
  • Iterative Method of Measurements for Chemical sensors (cs)
skos:prefLabel
  • Iterative Method of Measurements for Chemical sensors
  • Iterative Method of Measurements for Chemical sensors (en)
  • Iterative Method of Measurements for Chemical sensors (cs)
skos:notation
  • RIV/00216305:26220/02:PU29213!RIV06-GA0-26220___
http://linked.open.../vavai/riv/strany
  • 369-372
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GA102/00/0939), Z(MSM 262200022)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 649838
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26220/02:PU29213
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • IDEs; electrolytic conductivity; iterative measurement (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [EE85B046A3A5]
http://linked.open...v/mistoKonaniAkce
  • Brno
http://linked.open...i/riv/mistoVydani
  • Brno
http://linked.open...i/riv/nazevZdroje
  • EDS 2002 Electronic Devices and Systems Conference
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Hubálek, Jaromír
  • Vrba, Radimír
  • Krejčí, Jan
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
http://linked.open...n/vavai/riv/zamer
number of pages
http://purl.org/ne...btex#hasPublisher
  • Ing. Zdeněk Novotný CSc.
https://schema.org/isbn
  • 80-214-2180-0
http://localhost/t...ganizacniJednotka
  • 26220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 47 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software