Attributes | Values |
---|
rdf:type
| |
Description
| - Conventional confocal microscopes are based on dual scanning of a specimen by the images of a point source and of a point detector. Hence, their imaging mode is serial, i.e. the confocal image is obtained point-by-point. Parallel-mode confocal imaging is possible on the basis of broad-source image-plane holography. We adapted this classical-holography technique for real-time reflected-light microscopy. Imaging speed of the parallel-mode confocal microscope is not limited by any part of the optical system, but only by the image detection and storage systems. Both the image phase and the image amplitude are reconstructed from the interference signal. It was verified both theoretically and experimentally that the main imaging parameters of the microscope are comparable with those of a conventional confocal microscope. The only exception is the imaging speed, which can be much higher.
- Conventional confocal microscopes are based on dual scanning of a specimen by the images of a point source and of a point detector. Hence, their imaging mode is serial, i.e. the confocal image is obtained point-by-point. Parallel-mode confocal imaging is possible on the basis of broad-source image-plane holography. We adapted this classical-holography technique for real-time reflected-light microscopy. Imaging speed of the parallel-mode confocal microscope is not limited by any part of the optical system, but only by the image detection and storage systems. Both the image phase and the image amplitude are reconstructed from the interference signal. It was verified both theoretically and experimentally that the main imaging parameters of the microscope are comparable with those of a conventional confocal microscope. The only exception is the imaging speed, which can be much higher. (en)
|
Title
| - Parallel-mode confocal microscope
- Parallel-mode confocal microscope (en)
|
skos:prefLabel
| - Parallel-mode confocal microscope
- Parallel-mode confocal microscope (en)
|
skos:notation
| - RIV/00216305:26210/99:00000007!RIV/2000/MSM/262100
|
http://linked.open.../vavai/riv/strany
| |
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| - P(GA202/96/1520), P(GA202/98/P285)
|
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| - Chmelík, Radim
- Harna, Zdeněk
|
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/00216305:26210/99:00000007
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - confocal microscopy; holographic applications; real-time imaging (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| - US - Spojené státy americké
|
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| |
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| - Chmelík, Radim
- Harna, Zdeněk
|
issn
| |
number of pages
| |
http://localhost/t...ganizacniJednotka
| |