About: IMPACT OF CONVECTIVE PLUME AROUND HUMAN BODY ON TEQ MEASURED BY EQUIVALENT TEMPERATURE SENSORS     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • Equivalent temperature method in combination with Comfort zone diagram is relatively new and fast developing method for thermal comfort evaluation. Some measurement systems are based on small sensors which are fasten on the surface of a dummy or the real test person. The main problem in the cases when the sensors are used on the surface of real person is metabolic heat which generates convective plume around body. The authors refer about tests in the car cabin investigating the effect of convective plume on equivalent temperature measured by the sensors. Newton thermal manikin was used as generator of convective plume and also as the holder of the sensors. Dressman system was used for processing and logging of Teq from the sensors. It was concluded hat convective plume directly influences equivalent temperature measured by Dressman sensors and the degree of influence depends on air speed in vicinity of the manikin.
  • Equivalent temperature method in combination with Comfort zone diagram is relatively new and fast developing method for thermal comfort evaluation. Some measurement systems are based on small sensors which are fasten on the surface of a dummy or the real test person. The main problem in the cases when the sensors are used on the surface of real person is metabolic heat which generates convective plume around body. The authors refer about tests in the car cabin investigating the effect of convective plume on equivalent temperature measured by the sensors. Newton thermal manikin was used as generator of convective plume and also as the holder of the sensors. Dressman system was used for processing and logging of Teq from the sensors. It was concluded hat convective plume directly influences equivalent temperature measured by Dressman sensors and the degree of influence depends on air speed in vicinity of the manikin. (en)
Title
  • IMPACT OF CONVECTIVE PLUME AROUND HUMAN BODY ON TEQ MEASURED BY EQUIVALENT TEMPERATURE SENSORS
  • IMPACT OF CONVECTIVE PLUME AROUND HUMAN BODY ON TEQ MEASURED BY EQUIVALENT TEMPERATURE SENSORS (en)
skos:prefLabel
  • IMPACT OF CONVECTIVE PLUME AROUND HUMAN BODY ON TEQ MEASURED BY EQUIVALENT TEMPERATURE SENSORS
  • IMPACT OF CONVECTIVE PLUME AROUND HUMAN BODY ON TEQ MEASURED BY EQUIVALENT TEMPERATURE SENSORS (en)
skos:notation
  • RIV/00216305:26210/14:PU112256!RIV15-MSM-26210___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(EE2.3.30.0005)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 20584
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26210/14:PU112256
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Equivalent temperature, Thermal manikin, Measurement, Convective plume (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [F6619B800828]
http://linked.open...v/mistoKonaniAkce
  • Tampere
http://linked.open...i/riv/mistoVydani
  • Tampere, Finlad
http://linked.open...i/riv/nazevZdroje
  • Proceedings of Ambience14&10i3m
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Fišer, Jan
  • Bader, Viktor
  • Thomschke, Christoph
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • Tampere University of Technology
https://schema.org/isbn
  • 978-952-15-3269-6
http://localhost/t...ganizacniJednotka
  • 26210
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 41 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software