About: Analysis of Directly Measured Heat Transfer Coefficients During Special Experiments to Provide Better Understanding of Secondary Cooling During Continuous Casting Process     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • The cooling intensity of spray nozzles is a very important parameter in the secondary cooling zone of a continuous caster since it has strong impact on cast slab quality and operation. This parameter is characterized by the heat transfer coefficient (HTC), which is one of the boundary conditions for the heat conduction problem. At the Heat Transfer and Fluid Flow Laboratory of Brno University the cooling intensity of nozzles is measured on an experimental apparatus [1], [2]. Temperatures in a test plate are obtained from the measurements and surface temperatures as well as heat transfer coefficients are computed from these temperatures by an inverse heat conduction problem. The standard procedure for measuring the HTC is to position the spray nozzles below a preheated plate. In most continuous casters this configuration only exists in the run-out portion of the machine. The sprays in continuous casters are also spraying from above on to the cast slab and can spray onto the surface of the slab when it
  • The cooling intensity of spray nozzles is a very important parameter in the secondary cooling zone of a continuous caster since it has strong impact on cast slab quality and operation. This parameter is characterized by the heat transfer coefficient (HTC), which is one of the boundary conditions for the heat conduction problem. At the Heat Transfer and Fluid Flow Laboratory of Brno University the cooling intensity of nozzles is measured on an experimental apparatus [1], [2]. Temperatures in a test plate are obtained from the measurements and surface temperatures as well as heat transfer coefficients are computed from these temperatures by an inverse heat conduction problem. The standard procedure for measuring the HTC is to position the spray nozzles below a preheated plate. In most continuous casters this configuration only exists in the run-out portion of the machine. The sprays in continuous casters are also spraying from above on to the cast slab and can spray onto the surface of the slab when it (en)
Title
  • Analysis of Directly Measured Heat Transfer Coefficients During Special Experiments to Provide Better Understanding of Secondary Cooling During Continuous Casting Process
  • Analysis of Directly Measured Heat Transfer Coefficients During Special Experiments to Provide Better Understanding of Secondary Cooling During Continuous Casting Process (en)
skos:prefLabel
  • Analysis of Directly Measured Heat Transfer Coefficients During Special Experiments to Provide Better Understanding of Secondary Cooling During Continuous Casting Process
  • Analysis of Directly Measured Heat Transfer Coefficients During Special Experiments to Provide Better Understanding of Secondary Cooling During Continuous Casting Process (en)
skos:notation
  • RIV/00216305:26210/13:PU103891!RIV14-MSM-26210___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(EE2.3.20.0188), S
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 60523
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26210/13:PU103891
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Heat transfer coefficient, secondary cooling, continuous casting, cooling intensity (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [82A448025B73]
http://linked.open...v/mistoKonaniAkce
  • Pittsburgh, Pa
http://linked.open...i/riv/mistoVydani
  • Pittsburgh,
http://linked.open...i/riv/nazevZdroje
  • 2013 AISTech Conference Proceedings
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Blazek, Kenneth
  • Horský, Jaroslav
  • Moravec, Rudolf
  • Ondroušková, Jana
  • Yin, Hongbin
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • AISTech 2012
https://schema.org/isbn
  • 978-1-935117-32-2
http://localhost/t...ganizacniJednotka
  • 26210
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 41 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software