About: Laser ablation Methods for Analysis of Urinary Stones: Comparison Study Based on Calibration Pellets     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Methods based on laser ablation, such as Laser Induced Breakdown Spectroscopy (LIBS) and Laser Ablation Inductively Coupled Plasma Mass/Optical Emission Spectrometry (LA-ICP-MS/OES) are particularly suitable for urinary stones bulk and micro analysis. The aim of this study is to demonstrate the calibration capabilities and limitations of these techniques. There are no commercially available standards, which would correspond to urinary calculi matrix. Internal standardization is also difficult, mainly due to different crystalline phases in one kidney stone. Calibration pellets were prepared from human urinary stones with phosphate, oxalate and urate matrix. For this comparative study the most frequently used laser-ablation based analytical techniques were chosen, such as LIBS and LA-ICP-MS. Moreover some unconventional techniques such as simultaneous LIBS – LA-ICP-OES and laser ablation (LA) – LIBS were also utilized.
  • Methods based on laser ablation, such as Laser Induced Breakdown Spectroscopy (LIBS) and Laser Ablation Inductively Coupled Plasma Mass/Optical Emission Spectrometry (LA-ICP-MS/OES) are particularly suitable for urinary stones bulk and micro analysis. The aim of this study is to demonstrate the calibration capabilities and limitations of these techniques. There are no commercially available standards, which would correspond to urinary calculi matrix. Internal standardization is also difficult, mainly due to different crystalline phases in one kidney stone. Calibration pellets were prepared from human urinary stones with phosphate, oxalate and urate matrix. For this comparative study the most frequently used laser-ablation based analytical techniques were chosen, such as LIBS and LA-ICP-MS. Moreover some unconventional techniques such as simultaneous LIBS – LA-ICP-OES and laser ablation (LA) – LIBS were also utilized. (en)
Title
  • Laser ablation Methods for Analysis of Urinary Stones: Comparison Study Based on Calibration Pellets
  • Laser ablation Methods for Analysis of Urinary Stones: Comparison Study Based on Calibration Pellets (en)
skos:prefLabel
  • Laser ablation Methods for Analysis of Urinary Stones: Comparison Study Based on Calibration Pellets
  • Laser ablation Methods for Analysis of Urinary Stones: Comparison Study Based on Calibration Pellets (en)
skos:notation
  • RIV/00216305:26210/12:PU101656!RIV13-MSM-26210___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(ED1.1.00/02.0068), P(ME08002)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 146472
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26210/12:PU101656
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • LIBS, Laser ablation, urinary stones, calibration pellets (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [8EE9E90F4814]
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Kaiser, Jozef
http://localhost/t...ganizacniJednotka
  • 26210
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software