About: Influence of the PDA setup on a quality of velocity distributions     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Článek popisuje vliv nastavení PDA systému na získané rychlostní pole ve spreji. Chování systému bylo zkoumáno v oblasti lomového signálu, tzn. pro nastavení prijimaci optiky v rozsahu 30-80 stupnu. (cs)
  • The PDA (Phase Doppler Anemometer) is well known as one of the most useful techniques to study particle velocity and particle size distributions in two-phase flows. There are many variations to the setup of this diagnostic system, especially its geometrical parameters. Research of effervescent atomization, on a dense spray of the near-nozzle region in particular, shows that it is necessary to carry out a functionality analysis of the PDA system for such applications. The off-axis angle (scattering angle) has the essential influence on signal quality. Thus, a set of experiments has been carried out with one pressure nozzle under the same operation conditions for values of off-axis angle in the range of 30 -80 . The PDA user guide recommends a value of 73.7 as the optimum angle. Theoretically, there is no influence on acquired values of particular velocity, but this idea may be affected if the carrier of the velocity is not detected.
  • The PDA (Phase Doppler Anemometer) is well known as one of the most useful techniques to study particle velocity and particle size distributions in two-phase flows. There are many variations to the setup of this diagnostic system, especially its geometrical parameters. Research of effervescent atomization, on a dense spray of the near-nozzle region in particular, shows that it is necessary to carry out a functionality analysis of the PDA system for such applications. The off-axis angle (scattering angle) has the essential influence on signal quality. Thus, a set of experiments has been carried out with one pressure nozzle under the same operation conditions for values of off-axis angle in the range of 30 -80 . The PDA user guide recommends a value of 73.7 as the optimum angle. Theoretically, there is no influence on acquired values of particular velocity, but this idea may be affected if the carrier of the velocity is not detected. (en)
Title
  • Influence of the PDA setup on a quality of velocity distributions
  • Influence of the PDA setup on a quality of velocity distributions (en)
  • Vliv nastavení systému PDA na kvalitu získaných rychlostí (cs)
skos:prefLabel
  • Influence of the PDA setup on a quality of velocity distributions
  • Influence of the PDA setup on a quality of velocity distributions (en)
  • Vliv nastavení systému PDA na kvalitu získaných rychlostí (cs)
skos:notation
  • RIV/00216305:26210/07:PU68255!RIV08-GA0-26210___
http://linked.open.../vavai/riv/strany
  • 127-130
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GA101/06/0750)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 426457
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26210/07:PU68255
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Phase Doppler Anemometer, spray, two-phase flow, effervescent nozzle (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [2E37A198D6F8]
http://linked.open...v/mistoKonaniAkce
  • Holany-Litice
http://linked.open...i/riv/mistoVydani
  • Praha
http://linked.open...i/riv/nazevZdroje
  • 21st Sympozium on Anemometry, Proceedings
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Fišer, Jan
  • Jícha, Miroslav
  • Otáhal, Jan
  • Košner, Jan
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • Ústav pro hydrodynamiku AV ČR
https://schema.org/isbn
  • 978-80-87117-01-9
http://localhost/t...ganizacniJednotka
  • 26210
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software