| - Summary: This paper belongs to biomechanics of a hip joint section. It is engaged in problems with industrial tolerances for dimensions as one of the possible total hip prosthesis insufficiency. There can be a lot of reasons for failing of hip prosthesis (for example unfit materials, unfit construction, etc.). And there are also a lot of types of failure (for example break of prosthesis, pull-off of the components etc.). It was found that there is not uniform abrasion on removed parts from human body during the analysis on components of total hip prosthesis. On unused parts it was found that there are not the same tolerances for dimensions at the same components from different producers. During the pushing of the ball head into acetabulum we can find out that some pairs show out a clearance, some show the interference and in some cases we can say that they have a fine fit. 2D and 3D computation models of a ball head, acetabular fossa and pelvis were made, on which interference or clearance fits and r
- Summary: This paper belongs to biomechanics of a hip joint section. It is engaged in problems with industrial tolerances for dimensions as one of the possible total hip prosthesis insufficiency. There can be a lot of reasons for failing of hip prosthesis (for example unfit materials, unfit construction, etc.). And there are also a lot of types of failure (for example break of prosthesis, pull-off of the components etc.). It was found that there is not uniform abrasion on removed parts from human body during the analysis on components of total hip prosthesis. On unused parts it was found that there are not the same tolerances for dimensions at the same components from different producers. During the pushing of the ball head into acetabulum we can find out that some pairs show out a clearance, some show the interference and in some cases we can say that they have a fine fit. 2D and 3D computation models of a ball head, acetabular fossa and pelvis were made, on which interference or clearance fits and r (en)
|
Title
| - MECHANICAL ANALYSIS OF CONTACT BETWEEN BALL HEAD AND ACETABULAR FOSSA OF TOTAL HIP PROSTHESIS
- MECHANICAL ANALYSIS OF CONTACT BETWEEN BALL HEAD AND ACETABULAR FOSSA OF TOTAL HIP PROSTHESIS (en)
|
skos:prefLabel
| - MECHANICAL ANALYSIS OF CONTACT BETWEEN BALL HEAD AND ACETABULAR FOSSA OF TOTAL HIP PROSTHESIS
- MECHANICAL ANALYSIS OF CONTACT BETWEEN BALL HEAD AND ACETABULAR FOSSA OF TOTAL HIP PROSTHESIS (en)
|
skos:notation
| - RIV/00216305:26210/05:PU55220!RIV11-MSM-26210___
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/00216305:26210/05:PU55220
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - FEM analysis, total hip prosthesis, contact pressure, tolerances for dimensions (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...v/mistoKonaniAkce
| |
http://linked.open...i/riv/mistoVydani
| |
http://linked.open...i/riv/nazevZdroje
| - INŽENÝRSKÁ MECHANIKA 2005
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...iv/tvurceVysledku
| - Florian, Zdeněk
- Koukal, Milan
|
http://linked.open...vavai/riv/typAkce
| |
http://linked.open.../riv/zahajeniAkce
| |
http://linked.open...n/vavai/riv/zamer
| |
number of pages
| |
http://purl.org/ne...btex#hasPublisher
| |
https://schema.org/isbn
| |
http://localhost/t...ganizacniJednotka
| |