Attributes | Values |
---|
rdf:type
| |
Description
| - The article deals with the current practical problems associated with the swiming pool hall design issues and implementation of air conditioning systems. Describes the key causes of adverse conditions of internal microclimate. Points to the irreplaceable cooperation mutually cooperating professions, especially with regard to measurement and control of HVAC systems. Here, the article points out the lack of monitoring during the real operation of equipment, including quantification of actual operating costs. These are closely associated with a primary HVAC equipment design itself - pool unit. Its amenities, structure, designed air treatment and subsequent control with regard to the real operating conditions are a determining factor in the effective design and operation. Case studies are compared to alternative solutions and that %22as we used to%22 and %22with the active measurement and control system combined with advanced design methods. (en)
- Návrh vzduchotechnické jednotky pro odvod vlhkostní zátěže z prostorů bazénových hal apod. je spojený s mnoha okrajovými podmínkami, který tento návrh ovlivňují. Mezi ty základní patří požadovaná teplota a vlhkost vzduchu v interiéru větraného prostoru. Sestava jednotlivých prvků pro úpravy vzduchu je většinou navrhována na extrémní klimatické podmínky v exteriéru objektu v letním a zimním období. Jak ukazuje následující text, problémy s provozem zařízení a zajištění vnitřních mikroklimatických podmínek nastávají ne v projektech uvažovaných letních a zimních extrémů, ale v přechodných obdobích, kdy se venkovní klimatické podmínky v čase poměrně rychle mění a kdy jsou vzhledem k nasycení venkovního vzduchu vodní parou (vlhký podzim, období po dešti apod.) okrajové podmínky pro odvlhčovaní velmi nepříznivé.
- Návrh vzduchotechnické jednotky pro odvod vlhkostní zátěže z prostorů bazénových hal apod. je spojený s mnoha okrajovými podmínkami, který tento návrh ovlivňují. Mezi ty základní patří požadovaná teplota a vlhkost vzduchu v interiéru větraného prostoru. Sestava jednotlivých prvků pro úpravy vzduchu je většinou navrhována na extrémní klimatické podmínky v exteriéru objektu v letním a zimním období. Jak ukazuje následující text, problémy s provozem zařízení a zajištění vnitřních mikroklimatických podmínek nastávají ne v projektech uvažovaných letních a zimních extrémů, ale v přechodných obdobích, kdy se venkovní klimatické podmínky v čase poměrně rychle mění a kdy jsou vzhledem k nasycení venkovního vzduchu vodní parou (vlhký podzim, období po dešti apod.) okrajové podmínky pro odvlhčovaní velmi nepříznivé. (cs)
|
Title
| - Pool air conditioning - effective and operationally efficient design Pool air conditioning - effective and operationally efficient design Pool air conditioning - effective and operationally efficient design ol air conditioning - effective and operationally efficient design Pool air conditioning - effective and operationally efficient design Pool air conditioning - effective and operationally efficient design Pool airconditioning - effective and operationally efficient design (en)
- Bazénová vzduchotechnika – efektivní a provozně úsporné navrhování
- Bazénová vzduchotechnika – efektivní a provozně úsporné navrhování (cs)
|
skos:prefLabel
| - Pool air conditioning - effective and operationally efficient design Pool air conditioning - effective and operationally efficient design Pool air conditioning - effective and operationally efficient design ol air conditioning - effective and operationally efficient design Pool air conditioning - effective and operationally efficient design Pool air conditioning - effective and operationally efficient design Pool airconditioning - effective and operationally efficient design (en)
- Bazénová vzduchotechnika – efektivní a provozně úsporné navrhování
- Bazénová vzduchotechnika – efektivní a provozně úsporné navrhování (cs)
|
skos:notation
| - RIV/00216305:26110/12:PU100652!RIV13-MSM-26110___
|
http://linked.open...avai/predkladatel
| |
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/00216305:26110/12:PU100652
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - airconditioning, swiming pools, calculating of humidification, humidity (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| |
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| |
issn
| |
number of pages
| |
http://localhost/t...ganizacniJednotka
| |
is http://linked.open...avai/riv/vysledek
of | |