| - In this paper, a new study is presented, concerning the possibilities and limitations of bismuth- and antimony-film plated carbon paste electrodes, BiF-CPE and SbF-CPE, in combination with stripping voltammetry and mixed supporting electrolytes containing various complex-forming constituents. The experiments with both BiF-CPE and SbF-CPE in solutions containing halides (F-, Cl-, Br-, I-), pseudohalides (SCN-, CNO-, CN-), EDTA, or organic anions (tartrate, citrate) were focused on electroanalytical performance of both electrodes for the determination of Cd2+ and Pb2+ as model ions. Their behaviour was observed and discussed via the effects of the individual media upon the peak characteristics, base-line, as well as the dissolution peak of Bi/Sb. The results obtained have confirmed numerous relations and typical features that can be utilised in practical measurements.
- In this paper, a new study is presented, concerning the possibilities and limitations of bismuth- and antimony-film plated carbon paste electrodes, BiF-CPE and SbF-CPE, in combination with stripping voltammetry and mixed supporting electrolytes containing various complex-forming constituents. The experiments with both BiF-CPE and SbF-CPE in solutions containing halides (F-, Cl-, Br-, I-), pseudohalides (SCN-, CNO-, CN-), EDTA, or organic anions (tartrate, citrate) were focused on electroanalytical performance of both electrodes for the determination of Cd2+ and Pb2+ as model ions. Their behaviour was observed and discussed via the effects of the individual media upon the peak characteristics, base-line, as well as the dissolution peak of Bi/Sb. The results obtained have confirmed numerous relations and typical features that can be utilised in practical measurements. (en)
|
Title
| - Electroanalysis with Bismuth- and Antimony-Film Plated Carbon Paste Electrodes in Complex-Forming and Mixed Supporting Media
- Electroanalysis with Bismuth- and Antimony-Film Plated Carbon Paste Electrodes in Complex-Forming and Mixed Supporting Media (en)
|
skos:prefLabel
| - Electroanalysis with Bismuth- and Antimony-Film Plated Carbon Paste Electrodes in Complex-Forming and Mixed Supporting Media
- Electroanalysis with Bismuth- and Antimony-Film Plated Carbon Paste Electrodes in Complex-Forming and Mixed Supporting Media (en)
|
skos:notation
| - RIV/00216275:25310/11:39892640!RIV12-MSM-25310___
|
http://linked.open...avai/predkladatel
| |
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| - P(LC06035), P(MEB091139), Z(MSM0021627502)
|
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/00216275:25310/11:39892640
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - Complex-forming media; Antimony film; Bismuth film; Carbon paste electrodes; Electroanalysis (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| - Scientific Papers of the University of Pardubice, Series A, Faculty of Chemical Technology
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| - Stočes, Matěj
- Švancara, Ivan
- Bartoš, Martin
|
http://linked.open...n/vavai/riv/zamer
| |
issn
| |
number of pages
| |
http://localhost/t...ganizacniJednotka
| |
is http://linked.open...avai/riv/vysledek
of | |