About: Easily ionizable elements in analytical plasma pencil spectroscopy     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • Any discharge based excitation source may suffer from some matrix interferences. Especially easily ionizable elements from the group of alkali metals and also alkali earths can be a major source of these effects. Herein we present an experimental study describing the influence of these elements on measured spectral lines intensities and analytical results for some selected analytes. Similarly to previous studies with inductively coupled plasma a depression of the measured signals occurred in most cases. A strong decrease was observed in dependence on the concentration of the interferent while the influence of the analyte concentration is almost negligible. The dependence of the analyte signal decrease on the interferent concentration is not linear. Addition of e.g. sodium chloride causes a steep decrease of copper signal for a relatively narrow range 0-0.2 g l-1 of NaCl. Higher NaCl concentrations bring only moderate signal suppression.
  • Any discharge based excitation source may suffer from some matrix interferences. Especially easily ionizable elements from the group of alkali metals and also alkali earths can be a major source of these effects. Herein we present an experimental study describing the influence of these elements on measured spectral lines intensities and analytical results for some selected analytes. Similarly to previous studies with inductively coupled plasma a depression of the measured signals occurred in most cases. A strong decrease was observed in dependence on the concentration of the interferent while the influence of the analyte concentration is almost negligible. The dependence of the analyte signal decrease on the interferent concentration is not linear. Addition of e.g. sodium chloride causes a steep decrease of copper signal for a relatively narrow range 0-0.2 g l-1 of NaCl. Higher NaCl concentrations bring only moderate signal suppression. (en)
Title
  • Easily ionizable elements in analytical plasma pencil spectroscopy
  • Easily ionizable elements in analytical plasma pencil spectroscopy (en)
skos:prefLabel
  • Easily ionizable elements in analytical plasma pencil spectroscopy
  • Easily ionizable elements in analytical plasma pencil spectroscopy (en)
skos:notation
  • RIV/00216224:14740/14:00077812!RIV15-MSM-14740___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(ED1.1.00/02.0068), P(ED2.1.00/03.0086)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 12832
http://linked.open...ai/riv/idVysledku
  • RIV/00216224:14740/14:00077812
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • spectroscopy; plasma pencil; easily ionizable elements; analysis (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [ADBA6388EEEA]
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Hrdlička, Aleš
  • Kanický, Viktor
  • Otruba, Vítězslav
  • Slavíček, Pavel
  • Novosád, Lukáš
  • Dvořáková, Magda
http://localhost/t...ganizacniJednotka
  • 14740
Faceted Search & Find service v1.16.116 as of Feb 22 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3239 as of Feb 22 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 67 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software