About: A CONTINUOUS MODE OF OPERATION FOR LARGE VOLUME DOSING IN ANALYTICAL CARRIER AMPHOLYTE–FREE ISOELECTRIC FOCUSING OF PROTEINS APPLIED TO OFF–LINE DETECTION OF FRACTIONS     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Mass spectrometry (MS) is being increasingly used for analysis of proteome complex samples. To remove matrix interferences and to concentrate analytes prior to a MS measurement, sample preparation is often necessary. A useful method for this purpose is Carrier Ampholyte Free-Isoelectric Focusing (CAF-IEF). In this paper CAF-IEF of ampholytes was performed on a commercial apparatus EA101 (Villa Labeco, Slovakia) equipped with a specially made column for samples of large volumes (up to 0.5 ml). A new continuous mode without voltage interruption or electrolyte replacement was developed. In this mode, a low molecular pI marker (PIM 7.4), low concentrations of myoglobin and insulin (16 mg/l), respectively, were concentrated, and then 5-ul fractions collected for off-line analyses. The total time of focusing was 66 minutes. Concentration of PIM 7.4 in the fractions was increased up to 75 times (determined by UV-VIS spectrometry).
  • Mass spectrometry (MS) is being increasingly used for analysis of proteome complex samples. To remove matrix interferences and to concentrate analytes prior to a MS measurement, sample preparation is often necessary. A useful method for this purpose is Carrier Ampholyte Free-Isoelectric Focusing (CAF-IEF). In this paper CAF-IEF of ampholytes was performed on a commercial apparatus EA101 (Villa Labeco, Slovakia) equipped with a specially made column for samples of large volumes (up to 0.5 ml). A new continuous mode without voltage interruption or electrolyte replacement was developed. In this mode, a low molecular pI marker (PIM 7.4), low concentrations of myoglobin and insulin (16 mg/l), respectively, were concentrated, and then 5-ul fractions collected for off-line analyses. The total time of focusing was 66 minutes. Concentration of PIM 7.4 in the fractions was increased up to 75 times (determined by UV-VIS spectrometry). (en)
Title
  • A CONTINUOUS MODE OF OPERATION FOR LARGE VOLUME DOSING IN ANALYTICAL CARRIER AMPHOLYTE–FREE ISOELECTRIC FOCUSING OF PROTEINS APPLIED TO OFF–LINE DETECTION OF FRACTIONS
  • A CONTINUOUS MODE OF OPERATION FOR LARGE VOLUME DOSING IN ANALYTICAL CARRIER AMPHOLYTE–FREE ISOELECTRIC FOCUSING OF PROTEINS APPLIED TO OFF–LINE DETECTION OF FRACTIONS (en)
skos:prefLabel
  • A CONTINUOUS MODE OF OPERATION FOR LARGE VOLUME DOSING IN ANALYTICAL CARRIER AMPHOLYTE–FREE ISOELECTRIC FOCUSING OF PROTEINS APPLIED TO OFF–LINE DETECTION OF FRACTIONS
  • A CONTINUOUS MODE OF OPERATION FOR LARGE VOLUME DOSING IN ANALYTICAL CARRIER AMPHOLYTE–FREE ISOELECTRIC FOCUSING OF PROTEINS APPLIED TO OFF–LINE DETECTION OF FRACTIONS (en)
skos:notation
  • RIV/00216224:14310/06:00016304!RIV10-GA0-14310___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GA305/03/1100)
http://linked.open...iv/cisloPeriodika
  • 11
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 463472
http://linked.open...ai/riv/idVysledku
  • RIV/00216224:14310/06:00016304
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • capillary isoelectric focusing; neutralization reaction boundary; proteins; fractionation; injected large volume sample (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • DE - Spolková republika Německo
http://linked.open...ontrolniKodProRIV
  • [646BA4B89FB7]
http://linked.open...i/riv/nazevZdroje
  • Journal of Separation Science
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 29
http://linked.open...iv/tvurceVysledku
  • Pazourek, Jiří
  • Budilová, Jana
  • Pospíchal, Jan
  • Krásenský, Pavel
issn
  • 1615-9306
number of pages
http://localhost/t...ganizacniJednotka
  • 14310
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software