About: HPLC Determination of Phenol and Chlorophenols in Mixtures after Their Previous Preconcentration on Hydrophobic Sorbents     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Accubond C18 and Amberlite XAD2 SPE cartridges were found as suitable for preconcentration of 15 chlorophenols from 100 ml of 10% KCl or 10% NaCl solutions of pH 3. The acetonitrile eluates were evaporated under nitrogen to volume of 0.2 ml and their aliquots injected onto Supelcosil LC PAH 250x2.1 mm column. After gradient elution with phosphate buffer of pH 3.5 and methanol, the analytes were determined by means of diode array detector. The method was applied for determination of chlorophenols at 0.05 mg/l concentration after their previous preconcentration on Accubond C18 cartridge.
  • Accubond C18 and Amberlite XAD2 SPE cartridges were found as suitable for preconcentration of 15 chlorophenols from 100 ml of 10% KCl or 10% NaCl solutions of pH 3. The acetonitrile eluates were evaporated under nitrogen to volume of 0.2 ml and their aliquots injected onto Supelcosil LC PAH 250x2.1 mm column. After gradient elution with phosphate buffer of pH 3.5 and methanol, the analytes were determined by means of diode array detector. The method was applied for determination of chlorophenols at 0.05 mg/l concentration after their previous preconcentration on Accubond C18 cartridge. (en)
  • Accubond C18 and Amberlite XAD2 SPE cartridges were found as suitable for preconcentration of 15 chlorophenols from 100 ml of 10% KCl or 10% NaCl solutions of pH 3. The acetonitrile eluates were evaporated under nitrogen to volume of 0.2 ml and their aliquots injected onto Supelcosil LC PAH 250x2.1 mm column. After gradient elution with phosphate buffer of pH 3.5 and methanol, the analytes were determined by means of diode array detector. The method was applied for determination of chlorophenols at 0.05 mg/l concentration after their previous preconcentration on Accubond C18 cartridge. (cs)
Title
  • HPLC Determination of Phenol and Chlorophenols in Mixtures after Their Previous Preconcentration on Hydrophobic Sorbents (en)
  • Stanovení fenolu a chlorfenolů ve směsích metodou HPLC po předchozím zkoncentrování na pevné hydrofobní sorbenty
  • Stanovení fenolu a chlorfenolů ve směsích metodou HPLC po předchozím zkoncentrování na pevné hydrofobní sorbenty (cs)
skos:prefLabel
  • HPLC Determination of Phenol and Chlorophenols in Mixtures after Their Previous Preconcentration on Hydrophobic Sorbents (en)
  • Stanovení fenolu a chlorfenolů ve směsích metodou HPLC po předchozím zkoncentrování na pevné hydrofobní sorbenty
  • Stanovení fenolu a chlorfenolů ve směsích metodou HPLC po předchozím zkoncentrování na pevné hydrofobní sorbenty (cs)
skos:notation
  • RIV/00216224:14310/04:00009916!RIV08-MSM-14310___
http://linked.open.../vavai/riv/strany
  • 33-38
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(MSM 143100011), Z(MSM 263100020)
http://linked.open...iv/cisloPeriodika
  • 1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 587801
http://linked.open...ai/riv/idVysledku
  • RIV/00216224:14310/04:00009916
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Chlorophenols; Solid Phase Extraction; Narrow Bore HPLC (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • CZ - Česká republika
http://linked.open...ontrolniKodProRIV
  • [244193F8DADC]
http://linked.open...i/riv/nazevZdroje
  • Chemické Listy
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 98
http://linked.open...iv/tvurceVysledku
  • Hrdlička, Aleš
  • Kostrhounová, Romana
  • Sommer, Lumír
http://linked.open...n/vavai/riv/zamer
issn
  • 0009-2770
number of pages
http://localhost/t...ganizacniJednotka
  • 14310
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 110 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software