About: Searching for an appropriate image-guided radiotherapy method in prostate cancer – implications for safety margin     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Aims and background. The aim of the study was to compare the safety margin width using skin marks, pelvic skeleton-based targeting and adaptive protocol combining cone-beam computed tomography and kilovoltage image matching. Methods. A total of 434 consecutive patients were treated by image-guided radiotherapy from November 2008 to April 2012. An adaptive protocol combining cone-beam computed tomography and kilovoltage image matching with individualized safety margin calculation according to the Van Herk method was used in a total of 201 patients. The remaining 233 patients had their setup corrected using cone-beam computed tomography daily. Results. Analysis of the 3,137 cone-beam computed tomography images (201 patients) revealed that the margins between the clinical target volume and planning target volume with skin marks registration should be 1.24 cm in the anteroposterior, 0.98 cm in the craniocaudal, and 1.03 cm in the laterolateral direction.
  • Aims and background. The aim of the study was to compare the safety margin width using skin marks, pelvic skeleton-based targeting and adaptive protocol combining cone-beam computed tomography and kilovoltage image matching. Methods. A total of 434 consecutive patients were treated by image-guided radiotherapy from November 2008 to April 2012. An adaptive protocol combining cone-beam computed tomography and kilovoltage image matching with individualized safety margin calculation according to the Van Herk method was used in a total of 201 patients. The remaining 233 patients had their setup corrected using cone-beam computed tomography daily. Results. Analysis of the 3,137 cone-beam computed tomography images (201 patients) revealed that the margins between the clinical target volume and planning target volume with skin marks registration should be 1.24 cm in the anteroposterior, 0.98 cm in the craniocaudal, and 1.03 cm in the laterolateral direction. (en)
Title
  • Searching for an appropriate image-guided radiotherapy method in prostate cancer – implications for safety margin
  • Searching for an appropriate image-guided radiotherapy method in prostate cancer – implications for safety margin (en)
skos:prefLabel
  • Searching for an appropriate image-guided radiotherapy method in prostate cancer – implications for safety margin
  • Searching for an appropriate image-guided radiotherapy method in prostate cancer – implications for safety margin (en)
skos:notation
  • RIV/00216224:14110/14:00078689!RIV15-MSM-14110___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, V
http://linked.open...iv/cisloPeriodika
  • 5
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 44095
http://linked.open...ai/riv/idVysledku
  • RIV/00216224:14110/14:00078689
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Adaptive; Image guidance; Intensity-modulated radio-therapy; Prostate cancer; Radiation therapy (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GR - Řecká republika
http://linked.open...ontrolniKodProRIV
  • [995106208C68]
http://linked.open...i/riv/nazevZdroje
  • Tumori
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 100
http://linked.open...iv/tvurceVysledku
  • Dušek, Ladislav
  • Jarkovský, Jiří
  • Dolezel, Martin
  • Hlavka, Ales
  • Kolarova, Iveta
  • Odrazka, Karel
  • Valentova, Eva
  • Vanasek, Jaroslav
http://linked.open...ain/vavai/riv/wos
  • 000348335400008
issn
  • 0300-8916
number of pages
http://localhost/t...ganizacniJednotka
  • 14110
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software