About: IS THE PRESSURE IN THE AXIS OF THE LOWER LIMB DURING TOTAL KNEE ARTHROPLASTY SUFFICIENT TO IMITATE WEIGHT-BEARING?     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Gonarthrosis is non-inflammatory degenerative disease affecting the cartilage of the knee, often associated with mechanical axis deviation of the limbs. The definitive restoration of the mechanical axis of the limb during total knee arthroplasty using navigation system occurs during surgery and in the final phase of the operation during the solidification of bone cement, when the weight-bearing is imitated by pressure to heel in the axis of the limb. The goal of the study was to clarify whether this imitation of weight-bearing of the limb is sufficient in determining the mechanical axis of the limb. MATERIAL AND METHODS: We investigated the mechanical axis of the limb before and after total knee arthroplasty from measurements from weight-bearing X-ray and from the navigation system. We enrolled 113 patients. (en)
  • Gonartróza je nezánětlivé degenerativní onemocnění postihující chrupavku kolenního kloubu, často spojené s osovou úchylkou končetiny. K definitivnímu obnovení mechanické osy končetiny při implantaci totální endoprotézy s použitím navigace dochází v průběhu operace i v závěrečné fázi operace během tuhnutí kostního cementu, kdy zatížení končetiny je imitováno tlakem do paty v ose končetiny. Cílem práce bylo objasnit, zda je tato imitace zatížení končetiny při stanovení mechanické osy dostačující. MATERIÁL A METODIKA: V práci byla zjišťována mechanická osa končetiny před a po implantaci totální endoprotézy měřením z rtg snímku v zátěži a z údajů o mechanické ose v navigačním systému. Do studie bylo zařazeno 113 pacientů. VÝSLEDKY: Shoda mezi údaji z rtg snímku před operací a navigace na začátku operace byla u 14 pacientů (12%), rozdíl 1-2 stupně byl zjištěn u 36 pacientů (32 %), u 23 pacientů (20 %) byl rozdíl 3-4 stupně a u 40 pacientů (35%) byl rozdíl větší než 4 stupně.
  • Gonartróza je nezánětlivé degenerativní onemocnění postihující chrupavku kolenního kloubu, často spojené s osovou úchylkou končetiny. K definitivnímu obnovení mechanické osy končetiny při implantaci totální endoprotézy s použitím navigace dochází v průběhu operace i v závěrečné fázi operace během tuhnutí kostního cementu, kdy zatížení končetiny je imitováno tlakem do paty v ose končetiny. Cílem práce bylo objasnit, zda je tato imitace zatížení končetiny při stanovení mechanické osy dostačující. MATERIÁL A METODIKA: V práci byla zjišťována mechanická osa končetiny před a po implantaci totální endoprotézy měřením z rtg snímku v zátěži a z údajů o mechanické ose v navigačním systému. Do studie bylo zařazeno 113 pacientů. VÝSLEDKY: Shoda mezi údaji z rtg snímku před operací a navigace na začátku operace byla u 14 pacientů (12%), rozdíl 1-2 stupně byl zjištěn u 36 pacientů (32 %), u 23 pacientů (20 %) byl rozdíl 3-4 stupně a u 40 pacientů (35%) byl rozdíl větší než 4 stupně. (cs)
Title
  • IS THE PRESSURE IN THE AXIS OF THE LOWER LIMB DURING TOTAL KNEE ARTHROPLASTY SUFFICIENT TO IMITATE WEIGHT-BEARING? (en)
  • JE TLAK V OSE DOLNÍ KONČETINY DOSTAČUJÍCÍ PRO IMITACI ZÁTĚŽE PŘI IMPLANTACI TEP KOLENA?
  • JE TLAK V OSE DOLNÍ KONČETINY DOSTAČUJÍCÍ PRO IMITACI ZÁTĚŽE PŘI IMPLANTACI TEP KOLENA? (cs)
skos:prefLabel
  • IS THE PRESSURE IN THE AXIS OF THE LOWER LIMB DURING TOTAL KNEE ARTHROPLASTY SUFFICIENT TO IMITATE WEIGHT-BEARING? (en)
  • JE TLAK V OSE DOLNÍ KONČETINY DOSTAČUJÍCÍ PRO IMITACI ZÁTĚŽE PŘI IMPLANTACI TEP KOLENA?
  • JE TLAK V OSE DOLNÍ KONČETINY DOSTAČUJÍCÍ PRO IMITACI ZÁTĚŽE PŘI IMPLANTACI TEP KOLENA? (cs)
skos:notation
  • RIV/00216224:14110/14:00076558!RIV15-MSM-14110___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I
http://linked.open...iv/cisloPeriodika
  • 1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 23363
http://linked.open...ai/riv/idVysledku
  • RIV/00216224:14110/14:00076558
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Total knee arthroplasty; navigation system; mechanical axis of the limb (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • CZ - Česká republika
http://linked.open...ontrolniKodProRIV
  • [E5BA92201323]
http://linked.open...i/riv/nazevZdroje
  • Úrazová chirurgie
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 22
http://linked.open...iv/tvurceVysledku
  • Hart, Radek
  • Safi, Adel Mohammad Mahmoud
  • Baňas, Michal
  • Śváb, Pavel
issn
  • 1211-7080
number of pages
http://localhost/t...ganizacniJednotka
  • 14110
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software