About: Use of chemical dosimetry for comparison of ultrasound and ionising radiation of cavitation     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • A comparison of the effects of ultrasound (US) produced by US apparatuses in biological systems is one of the basic problems when studying US cavitation effects. A possibility for how to compare these effects are the indirect methods which use quantities characterizing the interaction of ionizing radiation with matter and which also converts these quantities to one common physical quantity. The first method employed a dosimeter composed of 50 % chloroform and 50 % re-distilled water (Taplin dosimeter). The other method used a iodide dosimeter - 0.5 M KI solution. After irradiation or US exposure, chemical changes occurred in both dosimeters, which were proportional to the exposure. The UZD 21 US disintegrator (22 kHz, 50 % power output) was used as a low frequency US source, and the BTL-07 therapeutic device (1 MHz, intensity of 2 W/cm2) was used as a high-frequency US source. For comparison, a 60Co gamma source was applied (gamma-rays 1.17 and 1.33 MeV, 14 PBq).
  • A comparison of the effects of ultrasound (US) produced by US apparatuses in biological systems is one of the basic problems when studying US cavitation effects. A possibility for how to compare these effects are the indirect methods which use quantities characterizing the interaction of ionizing radiation with matter and which also converts these quantities to one common physical quantity. The first method employed a dosimeter composed of 50 % chloroform and 50 % re-distilled water (Taplin dosimeter). The other method used a iodide dosimeter - 0.5 M KI solution. After irradiation or US exposure, chemical changes occurred in both dosimeters, which were proportional to the exposure. The UZD 21 US disintegrator (22 kHz, 50 % power output) was used as a low frequency US source, and the BTL-07 therapeutic device (1 MHz, intensity of 2 W/cm2) was used as a high-frequency US source. For comparison, a 60Co gamma source was applied (gamma-rays 1.17 and 1.33 MeV, 14 PBq). (en)
Title
  • Use of chemical dosimetry for comparison of ultrasound and ionising radiation of cavitation
  • Use of chemical dosimetry for comparison of ultrasound and ionising radiation of cavitation (en)
skos:prefLabel
  • Use of chemical dosimetry for comparison of ultrasound and ionising radiation of cavitation
  • Use of chemical dosimetry for comparison of ultrasound and ionising radiation of cavitation (en)
skos:notation
  • RIV/00216224:14110/07:00033444!RIV10-MSM-14110___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • S
http://linked.open...iv/cisloPeriodika
  • Suppl.1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 456916
http://linked.open...ai/riv/idVysledku
  • RIV/00216224:14110/07:00033444
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • cavitation; dosimetry; ultrasound; ionising radiation (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • CZ - Česká republika
http://linked.open...ontrolniKodProRIV
  • [F3E4E1E0DEB3]
http://linked.open...i/riv/nazevZdroje
  • Physiological Research
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 56
http://linked.open...iv/tvurceVysledku
  • Mornstein, Vojtěch
  • Kratochvíl, Bohdan
issn
  • 0862-8408
number of pages
http://localhost/t...ganizacniJednotka
  • 14110
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 47 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software