About: New method for the determination of carbamate and pyrethroid insecticides in water samples using on-line SPE fused core column chromatography     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • A new HPLC column-switching method using large volume sample injection and fused-core columns for on-line solid phase extraction have been developed for the determination of the following carbamates and pyrethroids: aldicarb, carbaryl, pirimicarb, carbofuran, kadethrin, flumethrin, fenpropathrin, fenoxycarb, tau-fluvalinate and fenvalerate, in surface water samples. Sudan I was used as internal standard. The proposed method was performed using 100 pi sample injection followed by an on-line solid phase extraction procedure and finally the compounds were identified and quantified by liquid chromatography with ultraviolet detection. The separation was carried out on C-18 reversed phase column based on fused-core particle technology. The influence of the injected sample volume, the variables affecting to SPE process and the conditions for the separation on an analytical column, were studied and optimized. The limits of detection ranged from 5.5 to 8.9 mu g L-1, and limits of quantification from 18.4 to 29.7 mu g L-1, while inter- and intra-day variability was under 15%. This new analytical procedure was satisfactorily applied for the determination of these organic pollutants in surface water samples located in Czech Republic. Concentration levels were found for some of these pollutants up to 26.11 mu g L-1 in the river Elbe and up to 34.53 mu g L-1 in the closed lakes samples.
  • A new HPLC column-switching method using large volume sample injection and fused-core columns for on-line solid phase extraction have been developed for the determination of the following carbamates and pyrethroids: aldicarb, carbaryl, pirimicarb, carbofuran, kadethrin, flumethrin, fenpropathrin, fenoxycarb, tau-fluvalinate and fenvalerate, in surface water samples. Sudan I was used as internal standard. The proposed method was performed using 100 pi sample injection followed by an on-line solid phase extraction procedure and finally the compounds were identified and quantified by liquid chromatography with ultraviolet detection. The separation was carried out on C-18 reversed phase column based on fused-core particle technology. The influence of the injected sample volume, the variables affecting to SPE process and the conditions for the separation on an analytical column, were studied and optimized. The limits of detection ranged from 5.5 to 8.9 mu g L-1, and limits of quantification from 18.4 to 29.7 mu g L-1, while inter- and intra-day variability was under 15%. This new analytical procedure was satisfactorily applied for the determination of these organic pollutants in surface water samples located in Czech Republic. Concentration levels were found for some of these pollutants up to 26.11 mu g L-1 in the river Elbe and up to 34.53 mu g L-1 in the closed lakes samples. (en)
Title
  • New method for the determination of carbamate and pyrethroid insecticides in water samples using on-line SPE fused core column chromatography
  • New method for the determination of carbamate and pyrethroid insecticides in water samples using on-line SPE fused core column chromatography (en)
skos:prefLabel
  • New method for the determination of carbamate and pyrethroid insecticides in water samples using on-line SPE fused core column chromatography
  • New method for the determination of carbamate and pyrethroid insecticides in water samples using on-line SPE fused core column chromatography (en)
skos:notation
  • RIV/00216208:11160/14:10282268!RIV15-MSM-11160___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(EE2.3.30.0022)
http://linked.open...iv/cisloPeriodika
  • November
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 32432
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11160/14:10282268
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Surface water; On-line solid phase extraction (on-line SPE); Large volume sample injection; Pyrethroids; Carbamates; Chromatography (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GB - Spojené království Velké Británie a Severního Irska
http://linked.open...ontrolniKodProRIV
  • [BEE211C12883]
http://linked.open...i/riv/nazevZdroje
  • Talanta
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 129
http://linked.open...iv/tvurceVysledku
  • Solich, Petr
  • Šatínský, Dalibor
  • Fernández Ramos, María Carolina
http://linked.open...ain/vavai/riv/wos
  • 000341463400080
issn
  • 0039-9140
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.talanta.2014.06.037
http://localhost/t...ganizacniJednotka
  • 11160
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 41 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software