About: In-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction for automation and downscaling of methylene blue active substances assay     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • A simple and rapid method for the determination of the methylene blue active substances assay based on in-syringe automation of magnetic stirring-assisted dispersive liquid-liquid microextraction was developed. The proposed method proved to be valid for the determination of anionic surfactant in waste, pond, well, tap, and drinking water samples. Sample mixing with reagents, extraction and phase separation were performed within the syringe of an automated syringe pump containing a magnetic stirring bar for homogenization and solvent dispersion. The syringe module was used upside-down to enable the use of chloroform as an extraction solvent of higher density than water. The calibration was found to be linear up to 0.3 mg/L using only 200 mu L of solvent and 4 mL of sample. The limits of detection (3 sigma) and quantification (10 sigma) were 7.0 mu g/L and 22 mu g/L, respectively. The relative standard deviation for 10 replicate determinations of 0.1 mg/L SBDS was below 3%. Concentrations of anionic surfactants in natural water samples were in the range of 0.032-0.213 mg/L and no significant differences towards the standard method were found. Standard additions gave analyte recoveries between 95% and 106% proving the general applicability and adequateness of the system to MBSA index determination. Compared to the tedious standard method requiring up to 50 mL of chloroform, the entire procedure took only 345 s using 250-times less solvent.
  • A simple and rapid method for the determination of the methylene blue active substances assay based on in-syringe automation of magnetic stirring-assisted dispersive liquid-liquid microextraction was developed. The proposed method proved to be valid for the determination of anionic surfactant in waste, pond, well, tap, and drinking water samples. Sample mixing with reagents, extraction and phase separation were performed within the syringe of an automated syringe pump containing a magnetic stirring bar for homogenization and solvent dispersion. The syringe module was used upside-down to enable the use of chloroform as an extraction solvent of higher density than water. The calibration was found to be linear up to 0.3 mg/L using only 200 mu L of solvent and 4 mL of sample. The limits of detection (3 sigma) and quantification (10 sigma) were 7.0 mu g/L and 22 mu g/L, respectively. The relative standard deviation for 10 replicate determinations of 0.1 mg/L SBDS was below 3%. Concentrations of anionic surfactants in natural water samples were in the range of 0.032-0.213 mg/L and no significant differences towards the standard method were found. Standard additions gave analyte recoveries between 95% and 106% proving the general applicability and adequateness of the system to MBSA index determination. Compared to the tedious standard method requiring up to 50 mL of chloroform, the entire procedure took only 345 s using 250-times less solvent. (en)
Title
  • In-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction for automation and downscaling of methylene blue active substances assay
  • In-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction for automation and downscaling of methylene blue active substances assay (en)
skos:prefLabel
  • In-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction for automation and downscaling of methylene blue active substances assay
  • In-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction for automation and downscaling of methylene blue active substances assay (en)
skos:notation
  • RIV/00216208:11160/14:10282008!RIV15-MSM-11160___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(EE2.3.30.0022)
http://linked.open...iv/cisloPeriodika
  • December
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 22122
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11160/14:10282008
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Sequential injection analysis; Methylene blue active substances assay; Anionic surfactants; In-syringe magnetic-stirring-assisted dispersive liquid-liquid microextraction (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GB - Spojené království Velké Británie a Severního Irska
http://linked.open...ontrolniKodProRIV
  • [C4E8CDEB01CB]
http://linked.open...i/riv/nazevZdroje
  • Talanta
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 130
http://linked.open...iv/tvurceVysledku
  • Cerda, Víctor
  • Horstkotte, Burkhard
  • Suárez, Ruth
http://linked.open...ain/vavai/riv/wos
  • 000341897800075
issn
  • 0039-9140
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.talanta.2014.06.063
http://localhost/t...ganizacniJednotka
  • 11160
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 112 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software