About: Fast and sensitive UHPLC methods with fluorescence and tandem mass spectrometry detection for the determination of tetracycline antibiotics in surface waters     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • In this paper two fast and highly sensitive ultra-high performance liquid chromatography (UHPLC) methods for the determination of tetracycline antibiotics (oxytetracycline, tetracycline, doxycycline, demeclocycline, chlortetracycline, minocycline and degradation product epitetracycline) in surface waters have been developed using fluorescence (FL) and mass spectrometry (MS) detection. ACQUITY UPLC BEH C8 and ACQUITY CSH C18 columns were employed for FL and MS detection, respectively, both packed with 1.7 mu m particles. Mixed-mode separation mechanism of CSH (charged surface technology) sorbent was found particularly useful in analysis of TCs, which possess problematic amphoteric structures. The FL methodology was based on chelation of tetracyclines with calcium ions to perform on-column derivatisation. The developed methods were compared in the terms of validation parameters including linearity, sensitivity, precision and accuracy. The linearity range for FL detection was within 7 ng mL(-1) to 50 mu g mL(-1) with method limit of detection (MLOD) as low as 0.2 ng mL(-1) for most of the analytes. MS detection showed even higher sensitivity reaching MLOD of 0.003 ngmL(-1), which is the highest sensitivity reported so far in analysis of TCs. Matrix matched calibration curves in the range of 0.01-50 ng mL(-1) were used for quantification to compensate for matrix effects with the correlation coefficients demonstrating good linearity (0.9940-0.9999). The extraction of the antibiotics from surface waters was performed using solid phase extraction with Oasis HLB cartridges. Accuracy was expressed as recovery with values ranging from 96.52% to 127.30% and from 91.66% to 123.70% for FL and MS detection, respectively.
  • In this paper two fast and highly sensitive ultra-high performance liquid chromatography (UHPLC) methods for the determination of tetracycline antibiotics (oxytetracycline, tetracycline, doxycycline, demeclocycline, chlortetracycline, minocycline and degradation product epitetracycline) in surface waters have been developed using fluorescence (FL) and mass spectrometry (MS) detection. ACQUITY UPLC BEH C8 and ACQUITY CSH C18 columns were employed for FL and MS detection, respectively, both packed with 1.7 mu m particles. Mixed-mode separation mechanism of CSH (charged surface technology) sorbent was found particularly useful in analysis of TCs, which possess problematic amphoteric structures. The FL methodology was based on chelation of tetracyclines with calcium ions to perform on-column derivatisation. The developed methods were compared in the terms of validation parameters including linearity, sensitivity, precision and accuracy. The linearity range for FL detection was within 7 ng mL(-1) to 50 mu g mL(-1) with method limit of detection (MLOD) as low as 0.2 ng mL(-1) for most of the analytes. MS detection showed even higher sensitivity reaching MLOD of 0.003 ngmL(-1), which is the highest sensitivity reported so far in analysis of TCs. Matrix matched calibration curves in the range of 0.01-50 ng mL(-1) were used for quantification to compensate for matrix effects with the correlation coefficients demonstrating good linearity (0.9940-0.9999). The extraction of the antibiotics from surface waters was performed using solid phase extraction with Oasis HLB cartridges. Accuracy was expressed as recovery with values ranging from 96.52% to 127.30% and from 91.66% to 123.70% for FL and MS detection, respectively. (en)
Title
  • Fast and sensitive UHPLC methods with fluorescence and tandem mass spectrometry detection for the determination of tetracycline antibiotics in surface waters
  • Fast and sensitive UHPLC methods with fluorescence and tandem mass spectrometry detection for the determination of tetracycline antibiotics in surface waters (en)
skos:prefLabel
  • Fast and sensitive UHPLC methods with fluorescence and tandem mass spectrometry detection for the determination of tetracycline antibiotics in surface waters
  • Fast and sensitive UHPLC methods with fluorescence and tandem mass spectrometry detection for the determination of tetracycline antibiotics in surface waters (en)
skos:notation
  • RIV/00216208:11160/13:10146049!RIV14-MSM-11160___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(KJB601100901), S
http://linked.open...iv/cisloPeriodika
  • May
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 74698
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11160/13:10146049
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Environmental contaminants; Surface waters; MS/MS; Tetracyclines; Mixed-mode stationary phases; UHPLC (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [A07976685954]
http://linked.open...i/riv/nazevZdroje
  • Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 927
http://linked.open...iv/tvurceVysledku
  • Solich, Petr
  • Nováková, Lucie
  • Šatínský, Dalibor
  • Škrášková, Karolina
  • Montenegro, Maria Conceicao B. S. M.
  • Pena, Angelina
  • Santos, Lúcia H. M. L. M.
http://linked.open...ain/vavai/riv/wos
  • 000318668000020
issn
  • 1570-0232
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.jchromb.2012.12.032
http://localhost/t...ganizacniJednotka
  • 11160
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software