About: A Fast HPLC Method for Determination of Vitamin E Acetate in Dietary Supplements Using Monolithic Column     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • A simple and fast high-performance liquid chromatography (HPLC) method with rapid separation on monolithic column has been developed for quantitative determination of vitamin E acetate in dietary supplements. Commercial samples of dietary supplements were extracted with 100 % methanol with the help of ultrasound bath. A 20-mu L sample volume of the filtered solution was directly injected into the HPLC system. Separation of ballast matrix, vitamin E acetate, and internal standard cholecalciferol was performed on the monolithic column Chromolith Performance RP-18e column (100 x 4.6 mm) with mobile phase methanol/water (98:2, v/v) at a flow rate of 2.0 mL min(-1) and at temperature 30 A degrees C. The detector was set at 290 nm. Under the optimum chromatographic conditions, standard calibration curve was measured with good linearity-correlation coefficient for vitamin E acetate (r = 0.9992; n = 6) between the peak areas and concentrations of vitamin E acetate. Accuracy of the method defined as a mean recovery was in the range 96.4-103.6 % for all dietary supplements. The intraday method precision was satisfactory and relative standard deviation of sample analysis including preparation and determination of different dietary supplements was in the range 1.1-3.6 %. The developed method has shown high sample throughput during sample preparation process and short time (3.5 min) of analysis.
  • A simple and fast high-performance liquid chromatography (HPLC) method with rapid separation on monolithic column has been developed for quantitative determination of vitamin E acetate in dietary supplements. Commercial samples of dietary supplements were extracted with 100 % methanol with the help of ultrasound bath. A 20-mu L sample volume of the filtered solution was directly injected into the HPLC system. Separation of ballast matrix, vitamin E acetate, and internal standard cholecalciferol was performed on the monolithic column Chromolith Performance RP-18e column (100 x 4.6 mm) with mobile phase methanol/water (98:2, v/v) at a flow rate of 2.0 mL min(-1) and at temperature 30 A degrees C. The detector was set at 290 nm. Under the optimum chromatographic conditions, standard calibration curve was measured with good linearity-correlation coefficient for vitamin E acetate (r = 0.9992; n = 6) between the peak areas and concentrations of vitamin E acetate. Accuracy of the method defined as a mean recovery was in the range 96.4-103.6 % for all dietary supplements. The intraday method precision was satisfactory and relative standard deviation of sample analysis including preparation and determination of different dietary supplements was in the range 1.1-3.6 %. The developed method has shown high sample throughput during sample preparation process and short time (3.5 min) of analysis. (en)
Title
  • A Fast HPLC Method for Determination of Vitamin E Acetate in Dietary Supplements Using Monolithic Column
  • A Fast HPLC Method for Determination of Vitamin E Acetate in Dietary Supplements Using Monolithic Column (en)
skos:prefLabel
  • A Fast HPLC Method for Determination of Vitamin E Acetate in Dietary Supplements Using Monolithic Column
  • A Fast HPLC Method for Determination of Vitamin E Acetate in Dietary Supplements Using Monolithic Column (en)
skos:notation
  • RIV/00216208:11160/13:10146035!RIV14-MSM-11160___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, S
http://linked.open...iv/cisloPeriodika
  • 2
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 58605
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11160/13:10146035
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Dietary supplements; HPLC; Monolithic columns; Vitamin E acetate (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GB - Spojené království Velké Británie a Severního Irska
http://linked.open...ontrolniKodProRIV
  • [DE7E758F2965]
http://linked.open...i/riv/nazevZdroje
  • Food Analytical Methods
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 6
http://linked.open...iv/tvurceVysledku
  • Solich, Petr
  • Šatínský, Dalibor
  • Brabcová, Ivana
  • Kovářová, Lenka
  • Havlíková, Lucie
http://linked.open...ain/vavai/riv/wos
  • 000316291500004
issn
  • 1936-9751
number of pages
http://bibframe.org/vocab/doi
  • 10.1007/s12161-012-9452-0
http://localhost/t...ganizacniJednotka
  • 11160
Faceted Search & Find service v1.16.116 as of Feb 22 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3239 as of Feb 22 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 80 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software