About: HILIC UHPLC-MS/MS for fast and sensitive bioanalysis: accounting for matrix effects in method development     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • Background: Matrix effects are considered to be a main obstacle of quantitative bioanalytical LC-MS/MS methods. Therefore it is often required to minimize them in order to increase method reliability. HILIC has been referenced as one of possible approaches. However, there is a lack of experimental evidence in scientific literature so far. Methodology: Matrix effects were evaluated using spiked serum samples after SPE and protein precipitation prior to UHPLC-ESI-MS/MS. Chromatography was performed in both HILIC and reversed-phase mode. The influence of the matrix effects on the signal response was assessed using a set of 34 compounds of pharmaceutical interest and post-extraction addition approach. Results: The advantages and drawbacks of the HILIC and reversed-phase chromatographic modes were compared and discussed in detail. Conclusion: HILIC demonstrated the potential to reduce the occurrence of matrix effects when a more thorough sample pretreatment procedure such as SPE was applied.
  • Background: Matrix effects are considered to be a main obstacle of quantitative bioanalytical LC-MS/MS methods. Therefore it is often required to minimize them in order to increase method reliability. HILIC has been referenced as one of possible approaches. However, there is a lack of experimental evidence in scientific literature so far. Methodology: Matrix effects were evaluated using spiked serum samples after SPE and protein precipitation prior to UHPLC-ESI-MS/MS. Chromatography was performed in both HILIC and reversed-phase mode. The influence of the matrix effects on the signal response was assessed using a set of 34 compounds of pharmaceutical interest and post-extraction addition approach. Results: The advantages and drawbacks of the HILIC and reversed-phase chromatographic modes were compared and discussed in detail. Conclusion: HILIC demonstrated the potential to reduce the occurrence of matrix effects when a more thorough sample pretreatment procedure such as SPE was applied. (en)
Title
  • HILIC UHPLC-MS/MS for fast and sensitive bioanalysis: accounting for matrix effects in method development
  • HILIC UHPLC-MS/MS for fast and sensitive bioanalysis: accounting for matrix effects in method development (en)
skos:prefLabel
  • HILIC UHPLC-MS/MS for fast and sensitive bioanalysis: accounting for matrix effects in method development
  • HILIC UHPLC-MS/MS for fast and sensitive bioanalysis: accounting for matrix effects in method development (en)
skos:notation
  • RIV/00216208:11160/13:10145994!RIV14-MSM-11160___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(EE2.3.30.0022)
http://linked.open...iv/cisloPeriodika
  • 19
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 77450
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11160/13:10145994
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • strategy; extraction; quantification; phospholipids; human plasma; protein precipitation; hydrophilic interaction chromatography; ultra high performance liquid chromatography; tandem mass spectrometry (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • PT - Portugalská republika
http://linked.open...ontrolniKodProRIV
  • [89C4B959092F]
http://linked.open...i/riv/nazevZdroje
  • Bioanalysis
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 5
http://linked.open...iv/tvurceVysledku
  • Solich, Petr
  • Nováková, Lucie
  • Vlčková, Hana
  • Havlíková, Lucie
http://linked.open...ain/vavai/riv/wos
  • 000324909800009
issn
  • 1757-6180
number of pages
http://bibframe.org/vocab/doi
  • 10.4155/bio.13.217
http://localhost/t...ganizacniJednotka
  • 11160
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 116 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software