  • The purpose of this study was to compare two different styles of prostate IGRT: bony landmark (BL) setup vs. fiducial markers (FM) setup. Twenty-nine prostate patients were treated with daily BL setup and 30 patients with daily FM setup. Delivered dose distribution was reconstructed on cone-beam CT (CBCT) acquired once a week immediately after the alignment. Target dose coverage was evaluated by the proportion of the CTV encompassed by the 95% isodose. Original plans employed 1 cm safety margin. Alternative plans assuming smaller 7 mm margin between CTV and PTV were evaluated in the same way. Rectal and bladder volumes were compared with initial ones. While the margin reduction in case of BL setup makes the prostate coverage significantly worse (p = 0.0003, McNemar's test), in case of FM setup with the reduced 7 mm margin, the prostate coverage is even better compared to BL setup with 10 mm margin (p = 0.049, Fisher's exact test). Moreover, partial volumes of organs at risk irradiated with a specific dose can be significantly lowered (p < 0.0001, unpaired t-test). Reducing of safety margin is not acceptable in case of BL setup, while the margin can be lowered from 10 mm to 7 mm in case of FM setup.
  • The purpose of this study was to compare two different styles of prostate IGRT: bony landmark (BL) setup vs. fiducial markers (FM) setup. Twenty-nine prostate patients were treated with daily BL setup and 30 patients with daily FM setup. Delivered dose distribution was reconstructed on cone-beam CT (CBCT) acquired once a week immediately after the alignment. Target dose coverage was evaluated by the proportion of the CTV encompassed by the 95% isodose. Original plans employed 1 cm safety margin. Alternative plans assuming smaller 7 mm margin between CTV and PTV were evaluated in the same way. Rectal and bladder volumes were compared with initial ones. While the margin reduction in case of BL setup makes the prostate coverage significantly worse (p = 0.0003, McNemar's test), in case of FM setup with the reduced 7 mm margin, the prostate coverage is even better compared to BL setup with 10 mm margin (p = 0.049, Fisher's exact test). Moreover, partial volumes of organs at risk irradiated with a specific dose can be significantly lowered (p < 0.0001, unpaired t-test). Reducing of safety margin is not acceptable in case of BL setup, while the margin can be lowered from 10 mm to 7 mm in case of FM setup. (en)
Title
  • Utilization of cone-beam CT for reconstruction of dose distribution delivered in image-guided radiotherapy of prostate carcinoma - bony landmark setup compared to fiducial markers setup
  • Utilization of cone-beam CT for reconstruction of dose distribution delivered in image-guided radiotherapy of prostate carcinoma - bony landmark setup compared to fiducial markers setup (en)
skos:prefLabel
  • Utilization of cone-beam CT for reconstruction of dose distribution delivered in image-guided radiotherapy of prostate carcinoma - bony landmark setup compared to fiducial markers setup
  • Utilization of cone-beam CT for reconstruction of dose distribution delivered in image-guided radiotherapy of prostate carcinoma - bony landmark setup compared to fiducial markers setup (en)
skos:notation
  • RIV/00216208:11150/13:10159108!RIV14-MSM-11150___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, S
http://linked.open...iv/cisloPeriodika
  • 3
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 113276
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11150/13:10159108
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • fiducial markers; prostate margin; cone-beam CT; IGRT (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • US - Spojené státy americké
http://linked.open...ontrolniKodProRIV
  • [00064B076E39]
http://linked.open...i/riv/nazevZdroje
  • Journal of applied clinical medical physics [electronic resource] / American College of Medical Physics
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 14
http://linked.open...iv/tvurceVysledku
  • Petera, Jiří
  • Vošmik, Milan
  • Hanuš, Josef
  • Hodek, Miroslav
  • Kašaová, Linda
  • Paluska, Petr
  • Jansa, Jan
  • Zouhar, Milan
  • Šefrová, Jana
  • Grepl, Jakub
  • Rousková, Lucie
http://linked.open...ain/vavai/riv/wos
  • 000318593600011
issn
  • 1526-9914
number of pages
http://localhost/t...ganizacniJednotka
  • 11150
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 39 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software