  • Objective: To compare Doppler flow Tei-indexes with standard intermittent transpulmonary thermodilution measurement with different hemodynamic loading conditions. Type of study: Experimental comparative study. Materials and methods: Total 48 piglets (6 weeks old, average weight 23kg) under general anesthesia, were divided into groups under cardiac loading conditions (at rest, with increased left ventricular afterload, with increased right ventricular preload). At 60 and 120 minutes the animals were examined by echocardiography and simultaneously transpulmonary thermodilution was used to measure cardiac output. Tei-indexes data were compared with invasively monitored haemodynamic data. Results: A total of 1632 parallel data were obtained. Correlation was found between values of right Tei-index and changes in right ventricular preload (p<0.05) and afterload (p<0.01). Correlation was also found between left Tei-index values and changes of left ventricular preload (p<0.001), afterload (p<0.001), stroke volume (p<0.01), and cardiac output (p<0.01). Conclusion: Tei-index as global myocardial performance selectively for the right and left ventricle can be recommended for monitoring of circulation and cardiac performance.
  • Objective: To compare Doppler flow Tei-indexes with standard intermittent transpulmonary thermodilution measurement with different hemodynamic loading conditions. Type of study: Experimental comparative study. Materials and methods: Total 48 piglets (6 weeks old, average weight 23kg) under general anesthesia, were divided into groups under cardiac loading conditions (at rest, with increased left ventricular afterload, with increased right ventricular preload). At 60 and 120 minutes the animals were examined by echocardiography and simultaneously transpulmonary thermodilution was used to measure cardiac output. Tei-indexes data were compared with invasively monitored haemodynamic data. Results: A total of 1632 parallel data were obtained. Correlation was found between values of right Tei-index and changes in right ventricular preload (p<0.05) and afterload (p<0.01). Correlation was also found between left Tei-index values and changes of left ventricular preload (p<0.001), afterload (p<0.001), stroke volume (p<0.01), and cardiac output (p<0.01). Conclusion: Tei-index as global myocardial performance selectively for the right and left ventricle can be recommended for monitoring of circulation and cardiac performance. (en)
Title
  • The echocardiographic Tei-index compared to transpulmonary thermodilution measurement with different hemodynamic biomodels
  • The echocardiographic Tei-index compared to transpulmonary thermodilution measurement with different hemodynamic biomodels (en)
skos:prefLabel
  • The echocardiographic Tei-index compared to transpulmonary thermodilution measurement with different hemodynamic biomodels
  • The echocardiographic Tei-index compared to transpulmonary thermodilution measurement with different hemodynamic biomodels (en)
skos:notation
  • RIV/00216208:11140/14:10227335!RIV15-MSM-11140___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, Z(MSM0021620819)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 12854
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11140/14:10227335
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • piglets; hemodynamics; transpulmonary thermodilution; Tei-index (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [AE957B85F05B]
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Kobr, Jiří
  • Pizingerová, Kateřina
http://linked.open...n/vavai/riv/zamer
http://localhost/t...ganizacniJednotka
  • 11140
Faceted Search & Find service v1.16.116 as of Feb 22 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3239 as of Feb 22 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 67 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software