About: Effect of Catheter-Based Patent Foramen Ovale Closure on the Occurrence of Arterial Bubbles in Scuba Divers     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • Objectives This study sought to evaluate the effect of catheter-based patent foramen ovale (PFO) closure on the occurrence of arterial bubbles after simulated dives. Background PFO is a risk factor of decompression sickness in divers due to paradoxical embolization of bubbles. To date, the effectiveness of catheter-based PFO closure in the reduction of arterial bubbles has not been demonstrated. Methods A total of 47 divers (age 35.4 +/- 8.6 years, 81% men) with a PFO (PFO group) or treated with a catheter-based PFO closure (closure group) were enrolled in this case-controlled observational trial. All divers were examined after a simulated dive in a hyperbaric chamber: 34 divers (19 in the PFO group, 15 in the closure group) performed a dive to 18 m for 80 min, and 13 divers (8 in the PFO group, 5 in the closure group) performed a dive to 50 m for 20 min. Within 60 min after surfacing, the presence of venous and arterial bubbles was assessed by transthoracic echocardiography and transcranial color-coded sonography, respectively. Results After the 18-m dive, venous bubbles were detected in 74% of divers in the PFO group versus 80% in the closure group (p = 1.0), and arterial bubbles were detected in 32% versus 0%, respectively (p = 0.02). After the 50-m dive, venous bubbles were detected in 88% versus 100%, respectively (p = 1.0), and arterial bubbles were detected in 88% versus 0%, respectively (p < 0.01). Conclusions No difference was observed in the occurrence of venous bubbles between the PFO and closure groups, but the catheter-based PFO closure led to complete elimination of arterial bubbles after simulated dives. (C) 2014 by the American College of Cardiology Foundation
  • Objectives This study sought to evaluate the effect of catheter-based patent foramen ovale (PFO) closure on the occurrence of arterial bubbles after simulated dives. Background PFO is a risk factor of decompression sickness in divers due to paradoxical embolization of bubbles. To date, the effectiveness of catheter-based PFO closure in the reduction of arterial bubbles has not been demonstrated. Methods A total of 47 divers (age 35.4 +/- 8.6 years, 81% men) with a PFO (PFO group) or treated with a catheter-based PFO closure (closure group) were enrolled in this case-controlled observational trial. All divers were examined after a simulated dive in a hyperbaric chamber: 34 divers (19 in the PFO group, 15 in the closure group) performed a dive to 18 m for 80 min, and 13 divers (8 in the PFO group, 5 in the closure group) performed a dive to 50 m for 20 min. Within 60 min after surfacing, the presence of venous and arterial bubbles was assessed by transthoracic echocardiography and transcranial color-coded sonography, respectively. Results After the 18-m dive, venous bubbles were detected in 74% of divers in the PFO group versus 80% in the closure group (p = 1.0), and arterial bubbles were detected in 32% versus 0%, respectively (p = 0.02). After the 50-m dive, venous bubbles were detected in 88% versus 100%, respectively (p = 1.0), and arterial bubbles were detected in 88% versus 0%, respectively (p < 0.01). Conclusions No difference was observed in the occurrence of venous bubbles between the PFO and closure groups, but the catheter-based PFO closure led to complete elimination of arterial bubbles after simulated dives. (C) 2014 by the American College of Cardiology Foundation (en)
Title
  • Effect of Catheter-Based Patent Foramen Ovale Closure on the Occurrence of Arterial Bubbles in Scuba Divers
  • Effect of Catheter-Based Patent Foramen Ovale Closure on the Occurrence of Arterial Bubbles in Scuba Divers (en)
skos:prefLabel
  • Effect of Catheter-Based Patent Foramen Ovale Closure on the Occurrence of Arterial Bubbles in Scuba Divers
  • Effect of Catheter-Based Patent Foramen Ovale Closure on the Occurrence of Arterial Bubbles in Scuba Divers (en)
skos:notation
  • RIV/00216208:11130/14:10282403!RIV15-MSM-11130___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, S
http://linked.open...iv/cisloPeriodika
  • 4
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 13162
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11130/14:10282403
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • patent foramen ovale; paradoxical embolization; decompression sickness; catheter-based closure (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • US - Spojené státy americké
http://linked.open...ontrolniKodProRIV
  • [D689A45648AB]
http://linked.open...i/riv/nazevZdroje
  • JACC: Cardiovascular Interventions
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 7
http://linked.open...iv/tvurceVysledku
  • Fiedler, Jiří
  • Veselka, Josef
  • Šefc, Luděk
  • Tomek, Aleš
  • Honěk, Jakub
  • Šrámek, Martin
  • Horváth, Martin
  • Januska, Jaroslav
  • Honek, Tomas
  • Novotný, Stepan
http://linked.open...ain/vavai/riv/wos
  • 000334509600012
issn
  • 1936-8798
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.jcin.2013.12.199
http://localhost/t...ganizacniJednotka
  • 11130
Faceted Search & Find service v1.16.116 as of Feb 22 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3239 as of Feb 22 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 67 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software