  • The aim of study was to introduce technical innovation of MIRPE which reduces the risk of cardiac injury. Modification of MIRPE method with semiflexible thoracoscope and sternum elevating technique has been used. Volkmann bone hook has been inserted percutaneously to the sternum. The hook elevates the sternum forward and enlarges the retrosternal space for safer passage of thoracoscopically guided introducer. Using semiflexible thoracoscope allows better view from various angles via one site of insertion. During the period 2005-2012, the MIRPE was performed on 29 girls and 151 boys; the mean age at the time of surgery was 15.9 years (range 13-18.7 years). The mean Haller index was 4.7 (range 2.7-20.5). The most common complication was pneumothorax (3.3 %) and the incidence of bar displacement was 2 %. The most serious complication was cardiac perforation when inserting Lorenz introducer. This occurred in a 16-year-old girl; she required urgent sternotomy with right atrial repair and recovered well. External elevation of sternum with the hook was used since this case. Subsequent 113 patients underwent surgery without any serious complications. Technical innovation using semiflexible thoracoscope and hook elevation of the sternum reduces the risk of cardiac injury. The hook opens the anterior mediastinum space effectively and makes the following dissection relatively safe and straightforward.
  • The aim of study was to introduce technical innovation of MIRPE which reduces the risk of cardiac injury. Modification of MIRPE method with semiflexible thoracoscope and sternum elevating technique has been used. Volkmann bone hook has been inserted percutaneously to the sternum. The hook elevates the sternum forward and enlarges the retrosternal space for safer passage of thoracoscopically guided introducer. Using semiflexible thoracoscope allows better view from various angles via one site of insertion. During the period 2005-2012, the MIRPE was performed on 29 girls and 151 boys; the mean age at the time of surgery was 15.9 years (range 13-18.7 years). The mean Haller index was 4.7 (range 2.7-20.5). The most common complication was pneumothorax (3.3 %) and the incidence of bar displacement was 2 %. The most serious complication was cardiac perforation when inserting Lorenz introducer. This occurred in a 16-year-old girl; she required urgent sternotomy with right atrial repair and recovered well. External elevation of sternum with the hook was used since this case. Subsequent 113 patients underwent surgery without any serious complications. Technical innovation using semiflexible thoracoscope and hook elevation of the sternum reduces the risk of cardiac injury. The hook opens the anterior mediastinum space effectively and makes the following dissection relatively safe and straightforward. (en)
Title
  • Technical innovation in minimally invasive repair of pectus excavatum
  • Technical innovation in minimally invasive repair of pectus excavatum (en)
skos:prefLabel
  • Technical innovation in minimally invasive repair of pectus excavatum
  • Technical innovation in minimally invasive repair of pectus excavatum (en)
skos:notation
  • RIV/00216208:11130/14:10196670!RIV15-MSM-11130___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I
http://linked.open...iv/cisloPeriodika
  • 1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 49431
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11130/14:10196670
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Sternum elevating technique; Wolkmann bone hook; Semiflexible thoracoscope; Minimally invasive repair of pectus excavatum; Pectus excavatum (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • CH - Švýcarská konfederace
http://linked.open...ontrolniKodProRIV
  • [76C599E2AB67]
http://linked.open...i/riv/nazevZdroje
  • Pediatric Surgery International
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 30
http://linked.open...iv/tvurceVysledku
  • Kučera, Alexandr
  • Rygl, Michal
  • Šnajdauf, Jiří
  • Mixa, Vladimír
  • Kynčl, Martin
  • Vyhnánek, Martin
http://linked.open...ain/vavai/riv/wos
  • 000329237900015
issn
  • 0179-0358
number of pages
http://bibframe.org/vocab/doi
  • 10.1007/s00383-013-3435-0
http://localhost/t...ganizacniJednotka
  • 11130
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 47 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software