  • Background: The purpose of this study is to test the agreement between energy expenditure estimate of the SenseWear (R) Armband Pro3 (SWA) (BodyMedia, Pittsburgh, PA) and the Omron HJ-720 (Omron Healthcare, Kyoto, Japan) step counter with indirect calorimetry (IC) as a gold standard in older individuals with type 1 and type 2 diabetes mellitus while walking on a treadmill. Subjects and Methods: In total, six men (60.3 +/- 3.1 years old) and 13 women (51.1 +/- 11.0 years old) with type 1 or type 2 diabetes mellitus were included in the study. Each subject performed three 15-min walking sessions with different combinations of speed and incline (3 km/h, 0%; 4 km/h, 0%; 5 km/h, 5%) on a treadmill. Energy expenditure (EE) was simultaneously measured by the SWA, Omron, and IC. Mean over-/underestimation and Pearson's correlation coefficients were used for statistical evaluation of the agreement between tested methods and IC. Results: At the speed of 3 km/h with 0% incline, mean overestimation of +81.19 +/- 23.81% was found for SWA (r = 0.79, P < 0.001) and +70.51 +/- 20.91% for Omron (r = 0.77, P < 0.001). At the speed of 4 km/h and 0% incline, mean overestimation found for SWA was +78.18 +/- 33.96% (r = 0.63, P < 0.01) and +75.77 +/- 33.36% for Omron (r = 0.52, P < 0.05). At the level of high-intensity exercise at the speed of 5 km/h and 5% incline, mean underestimation was -7.88 +/- 16.86% for SWA (r = 0.74, P < 0.001) and -7.37 +/- 16.07% for Omron (r = 0.75, P < 0.001). Conclusions: Both methods led to considerable overestimation of calculated EE in level walking and a relatively minor underestimation during fast uphill walking.
  • Background: The purpose of this study is to test the agreement between energy expenditure estimate of the SenseWear (R) Armband Pro3 (SWA) (BodyMedia, Pittsburgh, PA) and the Omron HJ-720 (Omron Healthcare, Kyoto, Japan) step counter with indirect calorimetry (IC) as a gold standard in older individuals with type 1 and type 2 diabetes mellitus while walking on a treadmill. Subjects and Methods: In total, six men (60.3 +/- 3.1 years old) and 13 women (51.1 +/- 11.0 years old) with type 1 or type 2 diabetes mellitus were included in the study. Each subject performed three 15-min walking sessions with different combinations of speed and incline (3 km/h, 0%; 4 km/h, 0%; 5 km/h, 5%) on a treadmill. Energy expenditure (EE) was simultaneously measured by the SWA, Omron, and IC. Mean over-/underestimation and Pearson's correlation coefficients were used for statistical evaluation of the agreement between tested methods and IC. Results: At the speed of 3 km/h with 0% incline, mean overestimation of +81.19 +/- 23.81% was found for SWA (r = 0.79, P < 0.001) and +70.51 +/- 20.91% for Omron (r = 0.77, P < 0.001). At the speed of 4 km/h and 0% incline, mean overestimation found for SWA was +78.18 +/- 33.96% (r = 0.63, P < 0.01) and +75.77 +/- 33.36% for Omron (r = 0.52, P < 0.05). At the level of high-intensity exercise at the speed of 5 km/h and 5% incline, mean underestimation was -7.88 +/- 16.86% for SWA (r = 0.74, P < 0.001) and -7.37 +/- 16.07% for Omron (r = 0.75, P < 0.001). Conclusions: Both methods led to considerable overestimation of calculated EE in level walking and a relatively minor underestimation during fast uphill walking. (en)
Title
  • Validation of Physical Activity Monitors in Individuals with Diabetes: Energy Expenditure Estimation by the Multisensor SenseWear Armband Pro3 and the Step Counter Omron HJ-720 Against Indirect Calorimetry During Walking
  • Validation of Physical Activity Monitors in Individuals with Diabetes: Energy Expenditure Estimation by the Multisensor SenseWear Armband Pro3 and the Step Counter Omron HJ-720 Against Indirect Calorimetry During Walking (en)
skos:prefLabel
  • Validation of Physical Activity Monitors in Individuals with Diabetes: Energy Expenditure Estimation by the Multisensor SenseWear Armband Pro3 and the Step Counter Omron HJ-720 Against Indirect Calorimetry During Walking
  • Validation of Physical Activity Monitors in Individuals with Diabetes: Energy Expenditure Estimation by the Multisensor SenseWear Armband Pro3 and the Step Counter Omron HJ-720 Against Indirect Calorimetry During Walking (en)
skos:notation
  • RIV/00216208:11130/13:10209753!RIV14-MSM-11130___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, S
http://linked.open...iv/cisloPeriodika
  • 5
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 113547
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11130/13:10209753
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • cost; field; adults; accuracy; pedometers; accelerometer; validity (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GB - Spojené království Velké Británie a Severního Irska
http://linked.open...ontrolniKodProRIV
  • [158773F3874B]
http://linked.open...i/riv/nazevZdroje
  • Diabetes Technology and Therapeutics
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 15
http://linked.open...iv/tvurceVysledku
  • Radvanský, Jiří
  • Procházka, Michal
  • Slabý, Kryštof
  • Machač, Stanislav
http://linked.open...ain/vavai/riv/wos
  • 000318477700009
issn
  • 1520-9156
number of pages
http://bibframe.org/vocab/doi
  • 10.1089/dia.2012.0235
http://localhost/t...ganizacniJednotka
  • 11130
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 77 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software