  • The aim was to compare methods of body fat measurement in different BMI groups. An additional aim was to discuss differences reflecting the structural and functional changes of fat tissue. The study group included 130 adult Caucasian women stratified by body mass index (BMI): 18-24.99 (n=30), 25-29.99 (n=26), 30-34.99 (n=33), 35-39.99 (n=30), and BMI }= 40 (n=11). Bioelectrical impedance was performed using Tanita TBF 410 GS, Bodystat 1500, and Omron BF 300. A caliper type Best was also applied. Correspondence of four methods with DEXA was assessed using the Bland-Altman and ANOVA analyses. Measurements by BIA were not significantly different from DEXA up to BMI of 30, but DEXA significantly overestimated in the higher BMI subgroup by all three methods. Caliper measurement significantly underestimated DEXA in all BMI subgroups. BIA methods overestimated DEXA for the obese subjects. Tanita did statistically the best. The Caliper test appeared less preferable than the BIA methods, especially in the higher BMI subgroup. DEXA and Caliper measurements seem to be the best estimate of structural (anatomical) fat quantity. We hypothesize that BIA methods could also measure some other physiopathological conditions like inflammation, hydration or cell infiltration of fat.
  • The aim was to compare methods of body fat measurement in different BMI groups. An additional aim was to discuss differences reflecting the structural and functional changes of fat tissue. The study group included 130 adult Caucasian women stratified by body mass index (BMI): 18-24.99 (n=30), 25-29.99 (n=26), 30-34.99 (n=33), 35-39.99 (n=30), and BMI }= 40 (n=11). Bioelectrical impedance was performed using Tanita TBF 410 GS, Bodystat 1500, and Omron BF 300. A caliper type Best was also applied. Correspondence of four methods with DEXA was assessed using the Bland-Altman and ANOVA analyses. Measurements by BIA were not significantly different from DEXA up to BMI of 30, but DEXA significantly overestimated in the higher BMI subgroup by all three methods. Caliper measurement significantly underestimated DEXA in all BMI subgroups. BIA methods overestimated DEXA for the obese subjects. Tanita did statistically the best. The Caliper test appeared less preferable than the BIA methods, especially in the higher BMI subgroup. DEXA and Caliper measurements seem to be the best estimate of structural (anatomical) fat quantity. We hypothesize that BIA methods could also measure some other physiopathological conditions like inflammation, hydration or cell infiltration of fat. (en)
Title
  • Does Impedance Measure a Functional State of the Body Fat?
  • Does Impedance Measure a Functional State of the Body Fat? (en)
skos:prefLabel
  • Does Impedance Measure a Functional State of the Body Fat?
  • Does Impedance Measure a Functional State of the Body Fat? (en)
skos:notation
  • RIV/00216208:11110/14:10285459!RIV15-MSM-11110___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, V
http://linked.open...iv/cisloPeriodika
  • Suppl. 2
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 12094
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11110/14:10285459
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Fat tissue functional properties; Anthropometric methods; Obesity; Fat mass; DEXA; Body composition (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • CZ - Česká republika
http://linked.open...ontrolniKodProRIV
  • [DC57751FBE1D]
http://linked.open...i/riv/nazevZdroje
  • Physiological Research
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 63
http://linked.open...iv/tvurceVysledku
  • Matoulek, Martin
  • Stránská, Zuzana
  • Svačina, Štěpán
  • Vilikus, Zdeněk
  • Klaschka, Jan
  • Svobodová, Šárka
  • Větrovská, Renata
http://linked.open...ain/vavai/riv/wos
  • 000345590400008
issn
  • 0862-8408
number of pages
http://localhost/t...ganizacniJednotka
  • 11110
Faceted Search & Find service v1.16.116 as of Feb 22 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3239 as of Feb 22 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 67 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software