About: Mechanical Properties of Mitral Allografts Are Not Reasonably Influenced by Cryopreservation in Sheep Model     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • A mitral allograft is used exceptionally in the mitral, as well as in the tricuspid position, mostly as an experimental surgical procedure. The authors decided to evaluate the possibility of inserting a cryopreserved mitral allograft into the tricuspid position in a sheep experimental model. Within the framework of this experimental project the mechanical properties of the cryopreserved mitral allograft were tested. A novel methodology studying the functional unit composed of mitral annulus, leaflet, chordae tendinaea, and papillary muscle is presented. A fiveparameter Maxwell model was applied to characterize the viscoelastic behavior of sheep mitral valves. A control group of 39 fresh mitral specimens and a test group of 13 cryopreserved mitral allografts from tissue bank were tested. The testing protocol consisted of six loading cycles with 1 mm elongation every 5 min. There was no significant difference in the mean values of the determined parameters (p}0.05) which confirms the main hypothesis that cryopreservation does not influence significantly material parameters characterizing the tissue mechanics. Slight discrepancy is observed in variances of viscous parameters suggesting that the values of the test group may be spread over larger interval due to the treatment.
  • A mitral allograft is used exceptionally in the mitral, as well as in the tricuspid position, mostly as an experimental surgical procedure. The authors decided to evaluate the possibility of inserting a cryopreserved mitral allograft into the tricuspid position in a sheep experimental model. Within the framework of this experimental project the mechanical properties of the cryopreserved mitral allograft were tested. A novel methodology studying the functional unit composed of mitral annulus, leaflet, chordae tendinaea, and papillary muscle is presented. A fiveparameter Maxwell model was applied to characterize the viscoelastic behavior of sheep mitral valves. A control group of 39 fresh mitral specimens and a test group of 13 cryopreserved mitral allografts from tissue bank were tested. The testing protocol consisted of six loading cycles with 1 mm elongation every 5 min. There was no significant difference in the mean values of the determined parameters (p}0.05) which confirms the main hypothesis that cryopreservation does not influence significantly material parameters characterizing the tissue mechanics. Slight discrepancy is observed in variances of viscous parameters suggesting that the values of the test group may be spread over larger interval due to the treatment. (en)
Title
  • Mechanical Properties of Mitral Allografts Are Not Reasonably Influenced by Cryopreservation in Sheep Model
  • Mechanical Properties of Mitral Allografts Are Not Reasonably Influenced by Cryopreservation in Sheep Model (en)
skos:prefLabel
  • Mechanical Properties of Mitral Allografts Are Not Reasonably Influenced by Cryopreservation in Sheep Model
  • Mechanical Properties of Mitral Allografts Are Not Reasonably Influenced by Cryopreservation in Sheep Model (en)
skos:notation
  • RIV/00179906:_____/11:10108352!RIV12-MZ0-00179906
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, S, V
http://linked.open...iv/cisloPeriodika
  • 3
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 211250
http://linked.open...ai/riv/idVysledku
  • RIV/00179906:_____/11:10108352
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Mitral valve; Viscoelastic properties; Maxwell model; Cryopreservation; Mitral allograft (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • CZ - Česká republika
http://linked.open...ontrolniKodProRIV
  • [EBE976AB5476]
http://linked.open...i/riv/nazevZdroje
  • Physiological Research
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 60
http://linked.open...iv/tvurceVysledku
  • Kochová, Petra
  • Klepáček, Jan
  • Vojáček, Jan
  • Špatenka, Jaroslav
  • Hlubocký, Jaroslav
  • Burkert, Jan
  • Mokráček, Aleš
  • Nováček, Vít
  • Pepper, John
http://linked.open...ain/vavai/riv/wos
  • 000293138600008
issn
  • 0862-8408
number of pages
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 78 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software