About: Calibration of Industrial Platinum Resistance Thermometers up to 700 °C     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Industrial grade platinum resistance thermometers were calibrated in the temperature range from 200°C to 700°C . Both wire-wound and thin-film sensor-based thermometers were investigated. The purpose of the study was to investigate thermometers which could be used in future coal power plants. The calibrations were performed in a vertical cesium heat-pipe furnace and in a horizontal and vertical sodium heat-pipe furnace. The reference thermometer was a standard platinum resistance thermometer calibrated at fixed points up to the aluminum point. In addition to calibration, various thermal tests including immersion measurements and thermal-cycling tests were performed. The stability of the sensors was determined by monitoring the ice-point resistance. Possible contamination of the sensors was determined by measuring the resistance ratio R(30°C)/R(10°C) several times during the measurement period. The calibration curves were compared with the ICE 60751 standard and International Temperature Scale 1990 (ITS-90) reference functions. Considerable changes were found in all tested thermometers. The wire-wound sensors were more stable than the thin-film sensors
  • Industrial grade platinum resistance thermometers were calibrated in the temperature range from 200°C to 700°C . Both wire-wound and thin-film sensor-based thermometers were investigated. The purpose of the study was to investigate thermometers which could be used in future coal power plants. The calibrations were performed in a vertical cesium heat-pipe furnace and in a horizontal and vertical sodium heat-pipe furnace. The reference thermometer was a standard platinum resistance thermometer calibrated at fixed points up to the aluminum point. In addition to calibration, various thermal tests including immersion measurements and thermal-cycling tests were performed. The stability of the sensors was determined by monitoring the ice-point resistance. Possible contamination of the sensors was determined by measuring the resistance ratio R(30°C)/R(10°C) several times during the measurement period. The calibration curves were compared with the ICE 60751 standard and International Temperature Scale 1990 (ITS-90) reference functions. Considerable changes were found in all tested thermometers. The wire-wound sensors were more stable than the thin-film sensors (en)
Title
  • Calibration of Industrial Platinum Resistance Thermometers up to 700 °C
  • Calibration of Industrial Platinum Resistance Thermometers up to 700 °C (en)
skos:prefLabel
  • Calibration of Industrial Platinum Resistance Thermometers up to 700 °C
  • Calibration of Industrial Platinum Resistance Thermometers up to 700 °C (en)
skos:notation
  • RIV/00177016:_____/14:#0001020!RIV15-MSM-00177016
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(7A11082)
http://linked.open...iv/cisloPeriodika
  • 3-4
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 6089
http://linked.open...ai/riv/idVysledku
  • RIV/00177016:_____/14:#0001020
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Calibration; Industrial; Platinum; Temperature; Thermometer (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • DE - Spolková republika Německo
http://linked.open...ontrolniKodProRIV
  • [6CE5E7C46B00]
http://linked.open...i/riv/nazevZdroje
  • International Jurnal of Thermophysics
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 35
http://linked.open...iv/tvurceVysledku
  • Strnad, Radek
  • Hahtela, O.
  • Heinonen, Martti
  • Kajastie, H.
  • Ojanen, M.
  • Riski, K.
issn
  • 1572-9567
number of pages
Faceted Search & Find service v1.16.116 as of Feb 22 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3239 as of Feb 22 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 80 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software