Attributes | Values |
---|
rdf:type
| |
Description
| - The recently developed new radiochromic gel dosimeter based on Turnbull blue dye formed by irradiation (the TBG dosimeter) does not exhibit dose pattern degradation due to diffusion effects as observed in the Fricke-gel dosimeter with xylenol orange incorporated into the gel matrix (the FXG dosimeter). The TBG dosimeter can be easily prepared and its optical properties enable the evaluation of the gel’s response using the cone beam optical computed tomography technique. It was found that the diffusion coefficient of the TBG dosimeter stored at 24°C is less than 4x10 3 mm2h-1, compared to the value of 7.6x10 1 mm2h-1 of the FXG dosimeter measured at the same temperature. Although the TBG dosimeter is less sensitive than the FXG dosimeter, its diffusion coefficient is practically negligible and, therefore, it offers large potential as a three dimensional dosimeter for applications encompassing sharp dose gradients such as high-dose-rate brachytherapy.
- The recently developed new radiochromic gel dosimeter based on Turnbull blue dye formed by irradiation (the TBG dosimeter) does not exhibit dose pattern degradation due to diffusion effects as observed in the Fricke-gel dosimeter with xylenol orange incorporated into the gel matrix (the FXG dosimeter). The TBG dosimeter can be easily prepared and its optical properties enable the evaluation of the gel’s response using the cone beam optical computed tomography technique. It was found that the diffusion coefficient of the TBG dosimeter stored at 24°C is less than 4x10 3 mm2h-1, compared to the value of 7.6x10 1 mm2h-1 of the FXG dosimeter measured at the same temperature. Although the TBG dosimeter is less sensitive than the FXG dosimeter, its diffusion coefficient is practically negligible and, therefore, it offers large potential as a three dimensional dosimeter for applications encompassing sharp dose gradients such as high-dose-rate brachytherapy. (en)
|
Title
| - New radiochromic gel for 3D dosimetry based on Turnbull blue: basic properties
- New radiochromic gel for 3D dosimetry based on Turnbull blue: basic properties (en)
|
skos:prefLabel
| - New radiochromic gel for 3D dosimetry based on Turnbull blue: basic properties
- New radiochromic gel for 3D dosimetry based on Turnbull blue: basic properties (en)
|
skos:notation
| - RIV/00177016:_____/09:#0000166!RIV11-MPO-00177016
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/00177016:_____/09:#0000166
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - Gel Dosimetry; Radiochromic Gels; Turnbull Blue (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| - US - Spojené státy americké
|
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| - Physics in Medicine and Biology
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| - Šolc, Jaroslav
- Spěváček, V.
|
http://linked.open...n/vavai/riv/zamer
| |
issn
| |
number of pages
| |
is http://linked.open...avai/riv/vysledek
of | |