About: Monte Carlo calculation of dose to water of a 106Ru COB-type ophthalmic plaque     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The concave eye applicators with 106Ru/106Rh or 90Sr/90Y beta-ray sources are world-wide used in brachytherapy for treating intraocular tumors. It raises the need to know the exact dose delivered by beta radiation to tumors but measurement of the dose to water (or tissue) is very difficult due to short range of electrons. The Monte Carlo code MCNPX has been used to calculate dose distributions from a COB-type 106Ru/106Rh ophthalmic applicator. The depth dose along the applicator central axis and the dose distribution on a spherical surface 1 mm above the plaque inner surface have been compared with measurement data provided by the manufacturer. For distances from 0.5 to 4 mm above the surface, the agreement was within 2.5 % and from 5 mm the difference increased from 6 % up to 25 % at 10 mm whereas the uncertainty of manufacturer data is 20 %. It is assumed that the difference is caused by nonuniformly distributed radioactivity over the applicator radioactive layer.
  • The concave eye applicators with 106Ru/106Rh or 90Sr/90Y beta-ray sources are world-wide used in brachytherapy for treating intraocular tumors. It raises the need to know the exact dose delivered by beta radiation to tumors but measurement of the dose to water (or tissue) is very difficult due to short range of electrons. The Monte Carlo code MCNPX has been used to calculate dose distributions from a COB-type 106Ru/106Rh ophthalmic applicator. The depth dose along the applicator central axis and the dose distribution on a spherical surface 1 mm above the plaque inner surface have been compared with measurement data provided by the manufacturer. For distances from 0.5 to 4 mm above the surface, the agreement was within 2.5 % and from 5 mm the difference increased from 6 % up to 25 % at 10 mm whereas the uncertainty of manufacturer data is 20 %. It is assumed that the difference is caused by nonuniformly distributed radioactivity over the applicator radioactive layer. (en)
Title
  • Monte Carlo calculation of dose to water of a 106Ru COB-type ophthalmic plaque
  • Monte Carlo calculation of dose to water of a 106Ru COB-type ophthalmic plaque (en)
skos:prefLabel
  • Monte Carlo calculation of dose to water of a 106Ru COB-type ophthalmic plaque
  • Monte Carlo calculation of dose to water of a 106Ru COB-type ophthalmic plaque (en)
skos:notation
  • RIV/00177016:_____/08:#0000163!RIV11-MPO-00177016
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • R
http://linked.open...iv/cisloPeriodika
  • 1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 380561
http://linked.open...ai/riv/idVysledku
  • RIV/00177016:_____/08:#0000163
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Monte Carlo; ophthalmic applicator; MCNP; beta radiation; simulation; dose to water (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • US - Spojené státy americké
http://linked.open...ontrolniKodProRIV
  • [0BB84DA8A2FD]
http://linked.open...i/riv/nazevZdroje
  • Journal of Physics: Conference Series
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 102
http://linked.open...iv/tvurceVysledku
  • Šolc, Jaroslav
issn
  • 1742-6596
number of pages
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software