  • Background and Purpose-We sought to evaluate the diagnostic accuracy of ultrasound criteria for recanalization during real-time transcranial Doppler monitoring of intra-arterial reperfusion procedures in acute ischemic stroke patients in an international, multicenter study. Methods-Consecutive acute ischemic stroke patients with proximal intracranial occlusions underwent intra-arterial reperfusion procedures with simultaneous real-time transcranial Doppler monitoring at 3 tertiary-care stroke centers. Residual flow signals at the site of angiographically confirmed occlusions were monitored at a constant transtemporal insonation angle using a standard head-frame. Recanalization was assessed simultaneously by digital subtraction angiography and ultrasound using thrombolysis in myocardial infarction and thrombolysis in brain ischemia (TIBI) criteria, respectively. Independent readers blinded to digital subtraction angiography performed validation of TIBI flow grades. The interrater reliability for assessment of TIBI grades was investigated. Results-We evaluated time-linked real-time digital subtraction angiography transcranial Doppler images from 96 diagnostic digital subtraction angiography runs during intra-arterial reperfusion procedures in 62 acute ischemic stroke patients (mean age, 59 +/- 17 years; 58% men; median baseline National Institutes of Health Stroke Scale score, 18 [interquartile range 12-21]; median time from symptom onset to intra-arterial procedure initiation, 240 minutes [ interquartile range 163-308]). The interrater reliability for evaluation of TIBI grades and assessment of recanalization was good (Cohen kappa: 0.838 and 0.874, respectively; P<0.001).
  • Background and Purpose-We sought to evaluate the diagnostic accuracy of ultrasound criteria for recanalization during real-time transcranial Doppler monitoring of intra-arterial reperfusion procedures in acute ischemic stroke patients in an international, multicenter study. Methods-Consecutive acute ischemic stroke patients with proximal intracranial occlusions underwent intra-arterial reperfusion procedures with simultaneous real-time transcranial Doppler monitoring at 3 tertiary-care stroke centers. Residual flow signals at the site of angiographically confirmed occlusions were monitored at a constant transtemporal insonation angle using a standard head-frame. Recanalization was assessed simultaneously by digital subtraction angiography and ultrasound using thrombolysis in myocardial infarction and thrombolysis in brain ischemia (TIBI) criteria, respectively. Independent readers blinded to digital subtraction angiography performed validation of TIBI flow grades. The interrater reliability for assessment of TIBI grades was investigated. Results-We evaluated time-linked real-time digital subtraction angiography transcranial Doppler images from 96 diagnostic digital subtraction angiography runs during intra-arterial reperfusion procedures in 62 acute ischemic stroke patients (mean age, 59 +/- 17 years; 58% men; median baseline National Institutes of Health Stroke Scale score, 18 [interquartile range 12-21]; median time from symptom onset to intra-arterial procedure initiation, 240 minutes [ interquartile range 163-308]). The interrater reliability for evaluation of TIBI grades and assessment of recanalization was good (Cohen kappa: 0.838 and 0.874, respectively; P<0.001). (en)
Title
  • Real-time Validation of Transcranial Doppler Criteria in Assessing Recanalization During Intra-arterial Procedures for Acute Ischemic Stroke An International, Multicenter Study
  • Real-time Validation of Transcranial Doppler Criteria in Assessing Recanalization During Intra-arterial Procedures for Acute Ischemic Stroke An International, Multicenter Study (en)
skos:prefLabel
  • Real-time Validation of Transcranial Doppler Criteria in Assessing Recanalization During Intra-arterial Procedures for Acute Ischemic Stroke An International, Multicenter Study
  • Real-time Validation of Transcranial Doppler Criteria in Assessing Recanalization During Intra-arterial Procedures for Acute Ischemic Stroke An International, Multicenter Study (en)
skos:notation
  • RIV/00159816:_____/13:00060609!RIV14-MZ0-00159816
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(ED1.100/02/0123)
http://linked.open...iv/cisloPeriodika
  • 2
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
  • Tsivgoulis, Georgios
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 101651
http://linked.open...ai/riv/idVysledku
  • RIV/00159816:_____/13:00060609
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • ultrasonics; transcranial Doppler; stroke; recanalization; angiography (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • US - Spojené státy americké
http://linked.open...ontrolniKodProRIV
  • [F33FD3A54BB7]
http://linked.open...i/riv/nazevZdroje
  • Stroke
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 44
http://linked.open...iv/tvurceVysledku
  • Tsivgoulis, Georgios
  • Alexandrov, Andrei V.
  • Giannopoulos, Sotirios
  • Vasdekis, Spyros N.
  • Barlinn, Kristian
  • Molina, Carlos A.
  • Athanasiadis, Dimitrios
  • Harrigan, Mark R.
  • Ribo, Marc
  • Rubiera, Marta
  • Shahripour, Reza Bavarsad
  • Stamboulis, Elefterios
http://linked.open...ain/vavai/riv/wos
  • 000313754800027
issn
  • 0039-2499
number of pages
http://bibframe.org/vocab/doi
  • 10.1161/STROKEAHA.112.675074
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 41 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software