Attributes | Values |
---|
rdf:type
| |
rdfs:seeAlso
| |
Description
| - . Purpose: To compare the thickness of the retinal nerve fibre layer (RNFL) in hydrophthalmic glaucomatous eyes in children with age-matched healthy controls using scanning laser polarimetry with variable corneal compensation (GDxVCC). Methods: Twenty hydrophthalmic eyes of 20 patients with the mean age of 10.64 +/- 3.02 years being treated for congenital or infantile glaucoma were included in the analysis. Evaluation of RNFL thickness measured by GDxVCC in standard Temporal-Superior-Nasal-Inferior-Temporal (TSNIT) parameters was performed. The results were compared to TSNIT values of an age-matched control group of 120 healthy children published recently as referential values. The correlation between horizontal corneal diameter and RNFL thickness in hydrophthalmic eyes was also investigated. Results: The mean +/- SD values in TSNIT Average, Superior Average, Inferior Average and TSNIT SD in hydrophthalmic eyes were 52.3 +/- 11.4, 59.7 +/- 17.1, 62.0 +/- 15.6 and 20.0 +/- 7.8 mu m, respectively. All these values were significantly lower compared to referential TSNIT parameters of age-matched healthy eyes (p = 0.021, p = 0.001, p = 0.003 and p = 0.018, respectively). A substantial number of hydrophthalmic eyes laid below the level of 5% probability of normality in respective TSNIT parameters: 30% of the eyes in TSNIT average, 50% of the eyes in superior average, 30% of the eyes in inferior average and 45% of the eyes in TSNIT SD. No significant correlation between enlarged corneal diameter and RNFL thickness was found. Conclusions: The mean values of all standard TSNIT parameters assessed using GDxVCC in hydrophthalmic glaucomatous eyes in children were significantly lower in comparison with referential values of healthy age-matched children.
- . Purpose: To compare the thickness of the retinal nerve fibre layer (RNFL) in hydrophthalmic glaucomatous eyes in children with age-matched healthy controls using scanning laser polarimetry with variable corneal compensation (GDxVCC). Methods: Twenty hydrophthalmic eyes of 20 patients with the mean age of 10.64 +/- 3.02 years being treated for congenital or infantile glaucoma were included in the analysis. Evaluation of RNFL thickness measured by GDxVCC in standard Temporal-Superior-Nasal-Inferior-Temporal (TSNIT) parameters was performed. The results were compared to TSNIT values of an age-matched control group of 120 healthy children published recently as referential values. The correlation between horizontal corneal diameter and RNFL thickness in hydrophthalmic eyes was also investigated. Results: The mean +/- SD values in TSNIT Average, Superior Average, Inferior Average and TSNIT SD in hydrophthalmic eyes were 52.3 +/- 11.4, 59.7 +/- 17.1, 62.0 +/- 15.6 and 20.0 +/- 7.8 mu m, respectively. All these values were significantly lower compared to referential TSNIT parameters of age-matched healthy eyes (p = 0.021, p = 0.001, p = 0.003 and p = 0.018, respectively). A substantial number of hydrophthalmic eyes laid below the level of 5% probability of normality in respective TSNIT parameters: 30% of the eyes in TSNIT average, 50% of the eyes in superior average, 30% of the eyes in inferior average and 45% of the eyes in TSNIT SD. No significant correlation between enlarged corneal diameter and RNFL thickness was found. Conclusions: The mean values of all standard TSNIT parameters assessed using GDxVCC in hydrophthalmic glaucomatous eyes in children were significantly lower in comparison with referential values of healthy age-matched children. (en)
|
Title
| - The retinal nerve fibre layer thickness in glaucomatous hydrophthalmic eyes assessed by scanning laser polarimetry with variable corneal compensation in comparison with age-matched healthy children
- The retinal nerve fibre layer thickness in glaucomatous hydrophthalmic eyes assessed by scanning laser polarimetry with variable corneal compensation in comparison with age-matched healthy children (en)
|
skos:prefLabel
| - The retinal nerve fibre layer thickness in glaucomatous hydrophthalmic eyes assessed by scanning laser polarimetry with variable corneal compensation in comparison with age-matched healthy children
- The retinal nerve fibre layer thickness in glaucomatous hydrophthalmic eyes assessed by scanning laser polarimetry with variable corneal compensation in comparison with age-matched healthy children (en)
|
skos:notation
| - RIV/00064203:_____/12:8253!RIV13-MZ0-00064203
|
http://linked.open...avai/predkladatel
| |
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/00064203:_____/12:8253
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - children; GDxVCC; glaucoma; hydrophthalmos; RNFL thickness; scanning laser polarimetry; optical coherence tomography; gdx vcc; neuropathy (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| |
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| - Filouš, Aleš
- Hložánek, Martin
- Ležatková, Pavlína
- Ošmera, Jakub
- Sedláčková, Petra
|
http://linked.open...ain/vavai/riv/wos
| |
issn
| |
number of pages
| |
is http://linked.open...avai/riv/vysledek
of | |