  • Objective: To evaluate the safety and effectiveness of novel biodegradable (BD) stents to treat bronchial anastomotic stenosis in patients after lung transplantation. Methods: Twenty BD stents were implanted endoscopically in six patients (median age 41.5 years (range 35-57 years)) with post-transplant bronchial anastomotic stenoses, between 2006 and 2010. All stents were custom-made from bio-absorbable polydioxanone (PDS). The median stent diameter was 12 mm (8-17 mm) and median length was 20 mm (12-30 mm). All patients were evaluated clinically, by bronchoscopy and high-definition computed tomography (CT). Results: The stenosis was initially relieved in all cases. There was no bleeding, perforation or displacement after BD stent implantation. Four patients needed multiple stenting for anastomotic re-stenosis. Median time to any re-stenting was 5 months (2-15 months). There was one sudden death, 1 year after the last BD stent implantation, from a pulmonary embolus. All five survivors are in good clinical condition up to 4 years' follow-up (median 40 months, range 7-48 months) since first stenting and intervention-free up to 44 months (median 24 months, range 7-44 months). Conclusions: This small pilot study shows that BD stents are a safe, effective and reliable alternative to classical metallic stents in patients with anastomotic stenosis after lung transplantation, and may avoid the need for permanent stenting. Crown Copyright (C) 2011 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
  • Objective: To evaluate the safety and effectiveness of novel biodegradable (BD) stents to treat bronchial anastomotic stenosis in patients after lung transplantation. Methods: Twenty BD stents were implanted endoscopically in six patients (median age 41.5 years (range 35-57 years)) with post-transplant bronchial anastomotic stenoses, between 2006 and 2010. All stents were custom-made from bio-absorbable polydioxanone (PDS). The median stent diameter was 12 mm (8-17 mm) and median length was 20 mm (12-30 mm). All patients were evaluated clinically, by bronchoscopy and high-definition computed tomography (CT). Results: The stenosis was initially relieved in all cases. There was no bleeding, perforation or displacement after BD stent implantation. Four patients needed multiple stenting for anastomotic re-stenosis. Median time to any re-stenting was 5 months (2-15 months). There was one sudden death, 1 year after the last BD stent implantation, from a pulmonary embolus. All five survivors are in good clinical condition up to 4 years' follow-up (median 40 months, range 7-48 months) since first stenting and intervention-free up to 44 months (median 24 months, range 7-44 months). Conclusions: This small pilot study shows that BD stents are a safe, effective and reliable alternative to classical metallic stents in patients with anastomotic stenosis after lung transplantation, and may avoid the need for permanent stenting. Crown Copyright (C) 2011 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved. (en)
Title
  • Novel biodegradable stents in the treatment of bronchial stenosis after lung transplantation
  • Novel biodegradable stents in the treatment of bronchial stenosis after lung transplantation (en)
skos:prefLabel
  • Novel biodegradable stents in the treatment of bronchial stenosis after lung transplantation
  • Novel biodegradable stents in the treatment of bronchial stenosis after lung transplantation (en)
skos:notation
  • RIV/00064203:_____/11:7024!RIV12-MZ0-00064203
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, V
http://linked.open...iv/cisloPeriodika
  • 3
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 216579
http://linked.open...ai/riv/idVysledku
  • RIV/00064203:_____/11:7024
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Transplantation; Lung; Stent; single running suture; knitted airway stent; complications; management; anastomoses (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [5EF0D2760A69]
http://linked.open...i/riv/nazevZdroje
  • European Journal of Cardio-Thoracic Surgery
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 40
http://linked.open...iv/tvurceVysledku
  • Lischke, Robert
  • Cerfolio, R.
  • Bertani, A.
  • Elliott, M. J.
  • Pozniak, Jiří
  • Rea, F.
  • Schmid, R.
  • Vondrys, D.
http://linked.open...ain/vavai/riv/wos
  • 000293824000025
issn
  • 1010-7940
number of pages
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software