  • Trochanteric fractures of the proximal femur are the most common lower limb fractures seen in clinical practice. Depending on the size, complexity, and stability of the fracture, it is possible to fixate the fracture using the Dynamic Hip Screw (DHS) system. Although complications and failures with the DHS system are infrequent, clinical practitioners have stressed the need to evaluate the stability of DHS in relation to its position in the bone during implantation. Stability of the DHS and the individual bone fragments is one of the key factors determining success of the treatment. Another important factor is the magnitude and method of loading of the bone tissue in the area surrounding the implanted parts of the DHS, which is produced during loading of the lower limb. To carry out this evaluation, we conducted a series of computational analyses using the Finite Element Method
  • Trochanteric fractures of the proximal femur are the most common lower limb fractures seen in clinical practice. Depending on the size, complexity, and stability of the fracture, it is possible to fixate the fracture using the Dynamic Hip Screw (DHS) system. Although complications and failures with the DHS system are infrequent, clinical practitioners have stressed the need to evaluate the stability of DHS in relation to its position in the bone during implantation. Stability of the DHS and the individual bone fragments is one of the key factors determining success of the treatment. Another important factor is the magnitude and method of loading of the bone tissue in the area surrounding the implanted parts of the DHS, which is produced during loading of the lower limb. To carry out this evaluation, we conducted a series of computational analyses using the Finite Element Method (en)
  • Trochanteric fractures of the proximal femur are the most common lower limb fractures seen in clinical practice. Depending on the size, complexity, and stability of the fracture, it is possible to fixate the fracture using the Dynamic Hip Screw (DHS) system. Although complications and failures with the DHS system are infrequent, clinical practitioners have stressed the need to evaluate the stability of DHS in relation to its position in the bone during implantation. Stability of the DHS and the individual bone fragments is one of the key factors determining success of the treatment. Another important factor is the magnitude and method of loading of the bone tissue in the area surrounding the implanted parts of the DHS, which is produced during loading of the lower limb. To carry out this evaluation, we conducted a series of computational analyses using the Finite Element Method (cs)
Title
  • Biomechanical analyses of proximal femur osteosynthesis by DHS system
  • Biomechanical analyses of proximal femur osteosynthesis by DHS system (en)
  • Biomechanical analyses of proximal femur osteosynthesis by DHS system (cs)
skos:prefLabel
  • Biomechanical analyses of proximal femur osteosynthesis by DHS system
  • Biomechanical analyses of proximal femur osteosynthesis by DHS system (en)
  • Biomechanical analyses of proximal femur osteosynthesis by DHS system (cs)
skos:notation
  • RIV/00064173:_____/11:#0000207!RIV12-MZ0-00064173
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • V, Z(MSM6840770012)
http://linked.open...iv/cisloPeriodika
  • 27
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 188378
http://linked.open...ai/riv/idVysledku
  • RIV/00064173:_____/11:#0000207
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • dynamic hip screw, femur fracture, FE analysis, bone fixation (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • CZ - Česká republika
http://linked.open...ontrolniKodProRIV
  • [B013BD0A561D]
http://linked.open...i/riv/nazevZdroje
  • Bulletin of Applied Mechanics
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 7
http://linked.open...iv/tvurceVysledku
  • Džupa, V.
  • Horák, Z.
  • Hrubina, M.
http://linked.open...n/vavai/riv/zamer
issn
  • 1801-1217
number of pages
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.116 as of Feb 22 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3239 as of Feb 22 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 67 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software