About: Acute outcomes of the STOP-VT study: Remote magnetic navigation with irrigated catheter to ablate ischemic VT     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Catheter ablation with standard irrigated catheters has been shown to reduce ventricular tachycardia (VT) episodes in studies. This can be a difficult procedure due to the complexity of the arrhythmia substrate. It is believed that remote magnetic navigation (RMN) provides additional benefit during mapping since the soft catheters do not promote additional PVCs or disrupt VT circuits during mapping. Approaches that define critical areas of the scar and potential VT sources during sinus rhythm have shown to be effective in treating this arrhythmia
  • Catheter ablation with standard irrigated catheters has been shown to reduce ventricular tachycardia (VT) episodes in studies. This can be a difficult procedure due to the complexity of the arrhythmia substrate. It is believed that remote magnetic navigation (RMN) provides additional benefit during mapping since the soft catheters do not promote additional PVCs or disrupt VT circuits during mapping. Approaches that define critical areas of the scar and potential VT sources during sinus rhythm have shown to be effective in treating this arrhythmia (en)
Title
  • Acute outcomes of the STOP-VT study: Remote magnetic navigation with irrigated catheter to ablate ischemic VT
  • Acute outcomes of the STOP-VT study: Remote magnetic navigation with irrigated catheter to ablate ischemic VT (en)
skos:prefLabel
  • Acute outcomes of the STOP-VT study: Remote magnetic navigation with irrigated catheter to ablate ischemic VT
  • Acute outcomes of the STOP-VT study: Remote magnetic navigation with irrigated catheter to ablate ischemic VT (en)
skos:notation
  • RIV/00023884:_____/10:#0000028!RIV11-MSM-00023884
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(ME 900)
http://linked.open...iv/cisloPeriodika
  • may
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 245319
http://linked.open...ai/riv/idVysledku
  • RIV/00023884:_____/10:#0000028
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Ventricular tachycardia, Catheter ablation (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • US - Spojené státy americké
http://linked.open...ontrolniKodProRIV
  • [D4625D77229D]
http://linked.open...i/riv/nazevZdroje
  • Heart Rhythm
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 7
http://linked.open...iv/tvurceVysledku
  • Petrů, Jan
  • Škoda, Jan
  • Šedivá, Lucie
  • Neužil, Petr
issn
  • 1547-5271
number of pages
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 75 GB memory in use)
Data on this page belongs to its respective rights holders.