About: Pulmonary Vein Isolation Using a Visually Guided Laser Balloon Catheter: The First 200-Patient Multicenter Clinical Experience     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • Background Because of the technical difficulty with achieving pulmonary vein (PV) isolation in the treatment of patients with paroxysmal atrial fibrillation, novel catheter designs to facilitate the procedure are in development. A visually guided laser ablation (VGLA) catheter was designed to allow the operator to directly visualize target tissue for ablation and then deliver laser energy to perform point-to-point circumferential ablation. Single-center studies have demonstrated favorable safety and efficacy. We sought to determine the multicenter feasibility, efficacy, and safety of performing PV isolation using the VGLA catheter. Methods and Results This study includes the first 200 paroxysmal atrial fibrillation patients treated with the VGLA catheter (33 operators, 15 centers). After transseptal puncture, the VGLA catheter was used to perform PV isolation. Electric isolation was assessed using a circular mapping catheter. Using the VGLA catheter, 98.8% (95% confidence interval, 97.8%-99.5%) of targeted PVs were isolated using a mean of 1.07 catheters per patient. Fluoroscopy and procedure times were 31 +/- 21 (mean +/- SD) and 200 +/- 54 minutes, respectively, and improved with operator experience. There were no instances of stroke, transient ischemic attack, atrioesophageal fistulas, or significant PV stenosis. There was a 2% incidence of cardiac tamponade and a 2.5% incidence of phrenic nerve palsy. At 12 months, the drug-free rate of freedom from atrial arrhythmias after 1 or 2 procedures was 60.2% (95% confidence interval, 52.7%-67.4%). Conclusions In this multicenter experience of the first 200 patients treated with the VGLA catheter, PV isolation can be achieved in virtually all patients using a single VGLA catheter with an efficacy similar to radiofrequency ablation.
  • Background Because of the technical difficulty with achieving pulmonary vein (PV) isolation in the treatment of patients with paroxysmal atrial fibrillation, novel catheter designs to facilitate the procedure are in development. A visually guided laser ablation (VGLA) catheter was designed to allow the operator to directly visualize target tissue for ablation and then deliver laser energy to perform point-to-point circumferential ablation. Single-center studies have demonstrated favorable safety and efficacy. We sought to determine the multicenter feasibility, efficacy, and safety of performing PV isolation using the VGLA catheter. Methods and Results This study includes the first 200 paroxysmal atrial fibrillation patients treated with the VGLA catheter (33 operators, 15 centers). After transseptal puncture, the VGLA catheter was used to perform PV isolation. Electric isolation was assessed using a circular mapping catheter. Using the VGLA catheter, 98.8% (95% confidence interval, 97.8%-99.5%) of targeted PVs were isolated using a mean of 1.07 catheters per patient. Fluoroscopy and procedure times were 31 +/- 21 (mean +/- SD) and 200 +/- 54 minutes, respectively, and improved with operator experience. There were no instances of stroke, transient ischemic attack, atrioesophageal fistulas, or significant PV stenosis. There was a 2% incidence of cardiac tamponade and a 2.5% incidence of phrenic nerve palsy. At 12 months, the drug-free rate of freedom from atrial arrhythmias after 1 or 2 procedures was 60.2% (95% confidence interval, 52.7%-67.4%). Conclusions In this multicenter experience of the first 200 patients treated with the VGLA catheter, PV isolation can be achieved in virtually all patients using a single VGLA catheter with an efficacy similar to radiofrequency ablation. (en)
Title
  • Pulmonary Vein Isolation Using a Visually Guided Laser Balloon Catheter: The First 200-Patient Multicenter Clinical Experience
  • Pulmonary Vein Isolation Using a Visually Guided Laser Balloon Catheter: The First 200-Patient Multicenter Clinical Experience (en)
skos:prefLabel
  • Pulmonary Vein Isolation Using a Visually Guided Laser Balloon Catheter: The First 200-Patient Multicenter Clinical Experience
  • Pulmonary Vein Isolation Using a Visually Guided Laser Balloon Catheter: The First 200-Patient Multicenter Clinical Experience (en)
skos:notation
  • RIV/00023001:_____/13:00058780!RIV14-MZ0-00023001
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • N
http://linked.open...iv/cisloPeriodika
  • 3
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 101010
http://linked.open...ai/riv/idVysledku
  • RIV/00023001:_____/13:00058780
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • visual guidance; pulmonary vein isolation; lasers; catheter ablation; atrial fibrillation (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • US - Spojené státy americké
http://linked.open...ontrolniKodProRIV
  • [199E86B5F91C]
http://linked.open...i/riv/nazevZdroje
  • Circulation-Arrhythmia and Electrophysiology
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 6
http://linked.open...iv/tvurceVysledku
  • Kautzner, Josef
  • Kuck, Karl-Heinz
  • Neužil, Petr
  • Horton, Rodney
  • Natale, Andrea
  • Schmidt, Boris
  • Dukkipati, Srinivas R.
  • Reddy, Vivek Y.
  • Doshi, Shephal K.
  • Gerstenfeld, Edward P.
  • McElderry, H. Thomas
  • Metzner, Andreas
  • Ruskin, Jeremy N.
  • Woollett, Ian
  • d'Avila, Andre
http://linked.open...ain/vavai/riv/wos
  • 000320760200012
issn
  • 1941-3149
number of pages
http://bibframe.org/vocab/doi
  • 10.1161/CIRCEP.113.000431
Faceted Search & Find service v1.16.116 as of Feb 22 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3239 as of Feb 22 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 82 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software