  • OBJECTIVES The aim of this multicenter study was to evaluate the device-and procedure-related safety of a novel force-sensing radiofrequency (RF) ablation catheter capable of measuring the real-time contact force (CF) and to present CF data and its possible implications on patient safety. BACKGROUND The clinical outcome of RF ablation for the treatment of cardiac arrhythmias may be affected by the CF between the catheter tip and the tissue. Insufficient CF may result in an ineffective lesion, whereas excessive CF may result in complications. METHODS Seventy-seven patients (43 with right-sided supraventricular tachycardia [SVT] and 34 with atrial fibrillation [AF]) received percutaneous ablation with the novel studied catheter. The CF applied and safety events related to the procedure were reported. RESULTS CF values at mapping ranged from 8 +/- 8 to 60 +/- 35 g and from 12 +/- 10 to 39 +/- 29 g in the SVT group and the LA group, respectively, showing a significant interinvestigator variability (P < .0001). High transient CFs (>100 g) were noted in 27 patients (79%) of the LA group. One device-related complication (tamponade, 3%) occurred in the AF group. CONCLUSIONS Catheter ablation using real-time CF technology is safe for the treatment of SVT and AF. High CFs may occur during catheter manipulation and not just during ablation, suggesting that measuring CF may provide additional useful information to the operator for safe catheter manipulation. In the future, CF-sensing catheters may also increase the effectiveness of RF ablations by allowing better control of the RF lesion size.
  • OBJECTIVES The aim of this multicenter study was to evaluate the device-and procedure-related safety of a novel force-sensing radiofrequency (RF) ablation catheter capable of measuring the real-time contact force (CF) and to present CF data and its possible implications on patient safety. BACKGROUND The clinical outcome of RF ablation for the treatment of cardiac arrhythmias may be affected by the CF between the catheter tip and the tissue. Insufficient CF may result in an ineffective lesion, whereas excessive CF may result in complications. METHODS Seventy-seven patients (43 with right-sided supraventricular tachycardia [SVT] and 34 with atrial fibrillation [AF]) received percutaneous ablation with the novel studied catheter. The CF applied and safety events related to the procedure were reported. RESULTS CF values at mapping ranged from 8 +/- 8 to 60 +/- 35 g and from 12 +/- 10 to 39 +/- 29 g in the SVT group and the LA group, respectively, showing a significant interinvestigator variability (P < .0001). High transient CFs (>100 g) were noted in 27 patients (79%) of the LA group. One device-related complication (tamponade, 3%) occurred in the AF group. CONCLUSIONS Catheter ablation using real-time CF technology is safe for the treatment of SVT and AF. High CFs may occur during catheter manipulation and not just during ablation, suggesting that measuring CF may provide additional useful information to the operator for safe catheter manipulation. In the future, CF-sensing catheters may also increase the effectiveness of RF ablations by allowing better control of the RF lesion size. (en)
Title
  • A novel radiofrequency ablation catheter using contact force sensing: Toccata study
  • A novel radiofrequency ablation catheter using contact force sensing: Toccata study (en)
skos:prefLabel
  • A novel radiofrequency ablation catheter using contact force sensing: Toccata study
  • A novel radiofrequency ablation catheter using contact force sensing: Toccata study (en)
skos:notation
  • RIV/00023001:_____/12:00055949!RIV13-MZ0-00023001
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • N
http://linked.open...iv/cisloPeriodika
  • 1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 120481
http://linked.open...ai/riv/idVysledku
  • RIV/00023001:_____/12:00055949
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Contact force; Supraventricular tachycardia; Catheter ablation; Atrial fibrillation; Ablation (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • US - Spojené státy americké
http://linked.open...ontrolniKodProRIV
  • [64670C37EB44]
http://linked.open...i/riv/nazevZdroje
  • Heart Rhythm
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 9
http://linked.open...iv/tvurceVysledku
  • Hindricks, Gerhard
  • Jais, Pierre
  • Kautzner, Josef
  • Kuck, Karl-Heinz
  • Neužil, Petr
  • Natale, Andrea
  • Herrera, Claudia
  • Lambert, Hendrik
  • Nakagawa, Hiroshi
  • Reddy, Vivek Y
  • Saoudi, Nadir
  • Schmidt, Boris
  • Shah, Dipen C
http://linked.open...ain/vavai/riv/wos
  • 000298640400005
issn
  • 1547-5271
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.hrthm.2011.08.021
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 112 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software