About: Solenoid coil for mouse-model MRI with a clinical 3-Tesla imager: body imaging     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • A solenoid coil was built for magnetic resonance imaging of the mice. A coil prototype composed of 5 turns, with a length of 4 cm and 2.5 cm radius was developed to acquire (whole) body mouse magnetic resonance images at 130 MHz and an insertable gradient coil set. Coil performance was measured using the Q factor for both the loaded and unloaded cases were 161.67 and 178.03, respectively. These Q factors compare very well with those values reported in the literature. The images were acquired with a clinical 3 T system equipped with a custom-built gradient insert coil and gradient echo image sequence. Both phantom and in vivo images showed good signal-to-noise ratio and uniformity. The electromagnetic interaction between the insertable coils and the solenoidal coil is poor, and no image artefacts are present in the whole-body image of the mouse. This preliminary experience has shown that consistent high quality MR images of the mice can be obtained using this particular hardware configuration, making
  • A solenoid coil was built for magnetic resonance imaging of the mice. A coil prototype composed of 5 turns, with a length of 4 cm and 2.5 cm radius was developed to acquire (whole) body mouse magnetic resonance images at 130 MHz and an insertable gradient coil set. Coil performance was measured using the Q factor for both the loaded and unloaded cases were 161.67 and 178.03, respectively. These Q factors compare very well with those values reported in the literature. The images were acquired with a clinical 3 T system equipped with a custom-built gradient insert coil and gradient echo image sequence. Both phantom and in vivo images showed good signal-to-noise ratio and uniformity. The electromagnetic interaction between the insertable coils and the solenoidal coil is poor, and no image artefacts are present in the whole-body image of the mouse. This preliminary experience has shown that consistent high quality MR images of the mice can be obtained using this particular hardware configuration, making (en)
Title
  • Solenoid coil for mouse-model MRI with a clinical 3-Tesla imager: body imaging
  • Solenoid coil for mouse-model MRI with a clinical 3-Tesla imager: body imaging (en)
skos:prefLabel
  • Solenoid coil for mouse-model MRI with a clinical 3-Tesla imager: body imaging
  • Solenoid coil for mouse-model MRI with a clinical 3-Tesla imager: body imaging (en)
skos:notation
  • RIV/00023001:_____/09:00002090!RIV10-MZ0-00023001
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • N
http://linked.open...iv/cisloPeriodika
  • 2
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 342264
http://linked.open...ai/riv/idVysledku
  • RIV/00023001:_____/09:00002090
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • mouse MRI; solenoid coil; electromagnetic simulation. (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • MX - Spojené státy mexické
http://linked.open...ontrolniKodProRIV
  • [A0E43691A35F]
http://linked.open...i/riv/nazevZdroje
  • Revista mexicana de física
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 55
http://linked.open...iv/tvurceVysledku
  • Jirák, Daniel
  • Hidalgo, SS
  • Rodriguez, AO
  • Solis, SE
http://linked.open...ain/vavai/riv/wos
  • 000265620100011
issn
  • 0035-001X
number of pages
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software