About: Clinical impact of multi-detector row CT on patients with pancreatic cancer     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Objectives: This study was designed to compare multidetector row computed tomography (MDCT) and CT-assisted hepatic arteriography (CTHA)/CT during arterial portography (CTAP)/angiography/contrast-enhanced CT (CECT) findings prospectively for accuracy in the detection of liver metastasis and vascular involvement of the tumor. Methods: The study included 43 patients with pancreatic cancer who were evaluated from September 2002 to December 2003. These patients underwent preoperative evaluation by angiography/CTHA/CTAP/CECT (7-mm thickness) and by MDCT (1.25-mm thickness). Results: The sensitivity, specificity, positive predictive value, and negative predictive value of liver metastasis diagnosis were all superior using MDCT relative to CTHA/CTAP. The diagnostic accuracy of liver metastasis for patients with tumors less than 10 mm in diameter was particularly superior with MDCT relative to CTHA/CTAP. The surgical and pathological findings of vascular involvement were more accurately diagnosed by MDC
  • Objectives: This study was designed to compare multidetector row computed tomography (MDCT) and CT-assisted hepatic arteriography (CTHA)/CT during arterial portography (CTAP)/angiography/contrast-enhanced CT (CECT) findings prospectively for accuracy in the detection of liver metastasis and vascular involvement of the tumor. Methods: The study included 43 patients with pancreatic cancer who were evaluated from September 2002 to December 2003. These patients underwent preoperative evaluation by angiography/CTHA/CTAP/CECT (7-mm thickness) and by MDCT (1.25-mm thickness). Results: The sensitivity, specificity, positive predictive value, and negative predictive value of liver metastasis diagnosis were all superior using MDCT relative to CTHA/CTAP. The diagnostic accuracy of liver metastasis for patients with tumors less than 10 mm in diameter was particularly superior with MDCT relative to CTHA/CTAP. The surgical and pathological findings of vascular involvement were more accurately diagnosed by MDC (en)
  • %22multidetector row%22 CT, CT asistovaná hepatální arteriografie (cs)
Title
  • Clinical impact of multi-detector row CT on patients with pancreatic cancer
  • Klinické důsledky vyšetření technikou %22multi-detector row%22 CT u pacientů s karcinomem pankreatu (cs)
  • Clinical impact of multi-detector row CT on patients with pancreatic cancer (en)
skos:prefLabel
  • Clinical impact of multi-detector row CT on patients with pancreatic cancer
  • Klinické důsledky vyšetření technikou %22multi-detector row%22 CT u pacientů s karcinomem pankreatu (cs)
  • Clinical impact of multi-detector row CT on patients with pancreatic cancer (en)
skos:notation
  • RIV/00023001:_____/07:00001561!RIV08-MZ0-00023001
http://linked.open.../vavai/riv/strany
  • 175-179
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • N
http://linked.open...iv/cisloPeriodika
  • 2
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 413905
http://linked.open...ai/riv/idVysledku
  • RIV/00023001:_____/07:00001561
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • pancreas neoplasm; multi-detector; CT (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • US - Spojené státy americké
http://linked.open...ontrolniKodProRIV
  • [75D7A4F84934]
http://linked.open...i/riv/nazevZdroje
  • Pancreas
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 34
http://linked.open...iv/tvurceVysledku
  • Yamamoto, H.
  • Matsui, Y.
  • Mergental, Hynek
  • Satoi, S.
  • Kamiyama, Y.
  • Komemushi, A.
  • Takai, S.
  • Tanigawa, N.
  • Toyokawa, H.
  • Yanagimoto, H.
issn
  • 0885-3177
number of pages
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software