About: Influence of biocompatible coated heart lung machine tubing set on fibrinogen function, assessed by the TEG Functional Fibrinogen     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Projekt, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • The goal of our project is to compare the impact of a biocompatible coated extracorporeal system with the non coated system on functional competency of fibrinogen and platellets. Patients will be randomly assigned to a group with a biocompatible coated system for extracorporeal circulation tubing set ( group C), or a group without this coating (group N). Each group will comprise of 75 patients. Despite standard preoperative tests (incl thrombocytes, INR, aPTT and DD), fibrinogen level will be obtained by the standard Von Clauss method and coagulation examination TEG and TEG Funtional fibrinogen (Haemoscope Corp. IL, USA) will be performed. Ratio of functional to total fibrinogen will be assessed. Measurements will be repeated 2 hours and 2 days after the operation. At the end, fibrinogen protection rate against functional damage, caused by both systems, will be evaluated. (en)
  • Cílem projektu je srovnání dopadu použití biokompatibilně potaženého povrchu mimotělního oběhu se systémem nepotaženým na funkční kompetenci fibrinogenu a trombocytů . Pacienti budou randomizováni do skupiny s biokompatibilně potaženým systémem pro mimotělní oběh ( skupina C) a systémem bez tohoto potažení (N). V každé skupině plánujeme 75 pacientů. Pacientům obou skupin budou kromě běžných předoperačních odběrů vyšetřena standartní laboratorní metodou dle Von Clausse hladina fibrinogenu a provedena vyšetření koagulace TEG i TEG Funkční Fibrinogen (Haemoscope Corporation, IL, USA). Stanovíme poměr funkčního fibrinogenu na celkovém fibrinogenu. Tyto odběry budou opakovány 2 hodiny po operaci a 2. pooperační den. Závěrem srovnáme míru protekce fibrinogenu i trombocytů v obou skupinách.
Title
  • Influence of biocompatible coated heart lung machine tubing set on fibrinogen function, assessed by the TEG Functional Fibrinogen (en)
  • Stanovení vlivu biokompatibiní úpravy vnitřního povrchu systému pro mimotělní oběh na funkci fibrinogenu metodou TEG Funkční Fibrinogen
skos:notation
  • NS9614
http://linked.open...avai/cep/aktivita
http://linked.open...kovaStatniPodpora
http://linked.open...ep/celkoveNaklady
http://linked.open...datumDodatniDoRIV
http://linked.open...i/cep/druhSouteze
http://linked.open...ep/duvernostUdaju
http://linked.open.../cep/fazeProjektu
http://linked.open...ai/cep/hlavniObor
http://linked.open...hodnoceniProjektu
http://linked.open...vai/cep/kategorie
http://linked.open.../cep/klicovaSlova
  • TEG; functional fibrinogen; extracorporeal circulation; biocompatible surface; cardiac surgery; blood loss; haemotherapy (en)
http://linked.open...ep/partnetrHlavni
http://linked.open...inujicichPrijemcu
http://linked.open...cep/pocetPrijemcu
http://linked.open...ocetSpoluPrijemcu
http://linked.open.../pocetVysledkuRIV
http://linked.open...enychVysledkuVRIV
http://linked.open.../prideleniPodpory
http://linked.open...iciPoslednihoRoku
http://linked.open...atUdajeProjZameru
http://linked.open.../vavai/cep/soutez
http://linked.open...usZobrazovaneFaze
http://linked.open...ai/cep/typPojektu
http://linked.open...ep/ukonceniReseni
http://linked.open...ep/zahajeniReseni
http://linked.open...jektu+dodavatelem
  • Biocompatible surface of extracorporeal circulation decreases in the early postoperative period of functional decline in the proportion of platelets. (en)
  • Biokompatibilní povrch systému mimotělního oběhu snižuje v časném pooperačním období pokles funkčního podílu trombocytů. (cs)
http://linked.open...tniCyklusProjektu
http://linked.open.../cep/klicoveSlovo
  • TEG
  • biocompatible surface
  • blood loss
  • cardiac surgery
  • extracorporeal circulation
  • functional fibrinogen
is http://linked.open...vavai/riv/projekt of
is http://linked.open...vavai/cep/projekt of
Faceted Search & Find service v1.16.116 as of Feb 22 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3239 as of Feb 22 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 67 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software