About: The Development and Innovations of Modern Detection Systems and Materials for Electroanalytical Measurements     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Projekt, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • Main Goals of the Project In modern electrochemical sensing, the stripping analysis mode, either anodic or catodic, allows ultratrace (micro-g/L and submicro-g/L) determinations of numerous analytes as it includes a unique in-situ analyte pre-concentration step. However, mercury that has been in use as a stripping electrode material for decades became unpopular due to its toxicity and inconvenience in handling. The question of toxicity is especially multiplied in case of applications of mercury film-based electrodes, which are prepared from aqueous solutions of extremely toxic mercury salts. Therefore, an intensive search for new metallic sensing surfaces that could adequately replace mercury is in great progress. One of the genuine solution introduced recently is the bismuth film electrode (BiFE). It should be pointed out that both teams involved in this project application have been pioneering in this research; this is also evident from some recent joint publications resulted on the basis of (en)
  • V moderních electrochemických měřeních umožňuje technika tzv. rozpouštěcí (stripping) analýzy a to buď v anodické nebo katodické verzi, stopová až ultrastopová (g/L a nižší) stanovení četných cílových látek (analytů) díky tomu, že zahrnuje jedinečný nahromaďovací kroku v uspořádání in-situ, tj. přímo během analýzy. Po dlouhá léta byly používány různé rtuťové elektrody, které se poslední dobou stávají poněkud nepopulární kvůli nepraktické manipulaci a zdravotní škodlivosti. Tento problém se ještě násobí, používají-li se k přípravě některých typů elektrod roztoky rtuťnatých solí, které jsou všeobecně považovány za vysoce toxické. Není proto divu, že se bouřlivě rozvíjí výzkum a hledání elektrod a obecně detekčních systémů z nových kovových materiálů, jež by mohly adekvátně rtuť nahradit. Jedním ze slibných kroků v tomto směru je nedávné zavedení tzv. bismutové filmové elektrody (BiFE) a poté i dalších příbuzných čidel na bázi bismutu (BiE). (Na tomto místě by mělo být zdůrazněn
Title
  • The Development and Innovations of Modern Detection Systems and Materials for Electroanalytical Measurements (en)
  • Vývoj a inovace moderních detekčních systémů a materiálů pro elektroanalytická měření
skos:notation
  • MEB090904
http://linked.open...avai/cep/aktivita
http://linked.open...kovaStatniPodpora
http://linked.open...ep/celkoveNaklady
http://linked.open...datumDodatniDoRIV
http://linked.open...i/cep/druhSouteze
http://linked.open...ep/duvernostUdaju
http://linked.open.../cep/fazeProjektu
http://linked.open...ai/cep/hlavniObor
http://linked.open...hodnoceniProjektu
http://linked.open...vai/cep/kategorie
http://linked.open.../cep/klicovaSlova
  • Electrodes; (Bio)sensors; Detectors; Membranes; New materials; Development and testing; Electroanalysis; Trace analysis (en)
http://linked.open...ep/partnetrHlavni
http://linked.open...inujicichPrijemcu
http://linked.open...cep/pocetPrijemcu
http://linked.open...ocetSpoluPrijemcu
http://linked.open.../pocetVysledkuRIV
http://linked.open...enychVysledkuVRIV
http://linked.open...lneniVMinulemRoce
http://linked.open.../prideleniPodpory
http://linked.open...iciPoslednihoRoku
http://linked.open...atUdajeProjZameru
http://linked.open.../vavai/cep/soutez
http://linked.open...usZobrazovaneFaze
http://linked.open...ai/cep/typPojektu
http://linked.open...ep/ukonceniReseni
http://linked.open.../cep/vedlejsiObor
http://linked.open...ep/zahajeniReseni
http://linked.open...jektu+dodavatelem
  • Projekt byl zaměřen na vývoj a ověřování nertuťových kovových elektrod s přední pozicí v současné elektroanalýze, orientované na postupy šetrné k životnímu prostředí. Výsledky byly zúročeny v 5 publikacích v mezinár. časopisech a cca 10 konf. sděleních. (cs)
  • Project has been focused on the development of non-mercury metal electrodes with a prominent position in modern, environmentally friendly electroanalysis. Results: 5 papers in international journals and ca. 10 conference contributions could be published. (en)
http://linked.open...tniCyklusProjektu
http://linked.open.../cep/klicoveSlovo
  • Electrodes
  • (Bio)sensors
  • Detectors
  • Development and testing
  • Electroanalysis
  • Membranes
  • New materials
is http://linked.open...vavai/cep/projekt of
Faceted Search & Find service v1.16.116 as of Feb 22 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3239 as of Feb 22 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 67 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software