About: Selective impedance cardiography for precise investigation of hemodynamic parameters     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Projekt, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • The aim of the project is the development of a new method allowing precise estimation of dynamic changes of stroke volume and blood flow. To measure stroke volume and pulse wave propagation we will use a new ISI-mbICG two-channel impedance cardiograph (developed at complainant workplace). ISI-mbICG permits the linking of multiple modules and the creation of up to 10-channel ICG monitor. ISI-mbICG enables simultaneous recording on limbs, neck and thorax. The selective filtering, controlled by heart beats, will be used to remove artefacts and to extract the information connected with blood flow only. The back reconstruction over 10 artefact free signals will permit blood flow mapping. We expect the contribution in the basic research of blood flow circulation and circulation control and in non-invasive and cheap clinical diagnosis of hemodynamics. (en)
  • Cílem projektu je vývoj původních metod pro přesné stanovení dynamických změn srdečního výdeje a krevního toku. Součástí projektu je i základní výzkum oběhových parametrů při různých zátěžových stavech, který nové metody umožní. Abychom mohli měřit srdeční výdej a vlastnosti šíření tlakové vlny použijeme nový dvoukanálový impedanční kardiograf ISI-mbICG, který byl vyvinut na našem pracovišti. ISI-mbICG umožňuje spojení více modulů a vytvoření až 10-ti kanálového ICG monitoru. Lze tak měřit současně a nezávisle na hrudníku, krku a končetinách. Pro vyhodnocení signálu ICG a odstranění artefaktů bude vyvinuta nová metoda využívající základní tepové frekvence. Spojení nové metody a vícekanálového měření umožní mapování krevního toku. Předpokládáme výrazný přínos metody pro základní výzkum krevní cirkulace a neinvazivní a levnou klinickou diagnostiku stavu krevního oběhu.
Title
  • Selective impedance cardiography for precise investigation of hemodynamic parameters (en)
  • Selektivní impedanční kardiografie pro přesné stanovení hemodynamických parametrů krevní cirkulace
skos:notation
  • IAA200650801
http://linked.open...avai/cep/aktivita
http://linked.open...kovaStatniPodpora
http://linked.open...ep/celkoveNaklady
http://linked.open...datumDodatniDoRIV
http://linked.open...i/cep/druhSouteze
http://linked.open...ep/duvernostUdaju
http://linked.open.../cep/fazeProjektu
http://linked.open...ai/cep/hlavniObor
http://linked.open...hodnoceniProjektu
http://linked.open...vai/cep/kategorie
http://linked.open.../cep/klicovaSlova
  • stroke volume; impedance cardiography; blood flow (en)
http://linked.open...ep/partnetrHlavni
http://linked.open...inujicichPrijemcu
http://linked.open...cep/pocetPrijemcu
http://linked.open...ocetSpoluPrijemcu
http://linked.open.../pocetVysledkuRIV
http://linked.open...enychVysledkuVRIV
http://linked.open...lneniVMinulemRoce
http://linked.open.../prideleniPodpory
http://linked.open...iciPoslednihoRoku
http://linked.open...atUdajeProjZameru
http://linked.open.../vavai/cep/soutez
http://linked.open...usZobrazovaneFaze
http://linked.open...ai/cep/typPojektu
http://linked.open...ep/ukonceniReseni
http://linked.open.../cep/vedlejsiObor
http://linked.open...ep/zahajeniReseni
http://linked.open...jektu+dodavatelem
  • The result of the project is completed development of device to measure human whole-body impedance cardiography. The device provides new information for non-invasive measurement of dynamic properties of blood circulation and the state of arterial system. (en)
  • Výsledkem projektu je ukončený vývoj experimentálního přístroje pro měření humánní celotělové impedanční kardiografie. Přístroj přináší zcela nové informace pro neinvazivní měření dynamických vlastností krevního oběhu a stavu arteriálního systému. (cs)
http://linked.open...tniCyklusProjektu
http://linked.open.../cep/klicoveSlovo
  • stroke volume
  • impedance cardiography
is http://linked.open...vavai/riv/projekt of
is http://linked.open...vavai/cep/projekt of
Faceted Search & Find service v1.16.116 as of Feb 22 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3239 as of Feb 22 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 80 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software