Description
  • Langmuir probe can measure parameters of the low temperature plasma with acceptable precision only at low pressures. At higher pressures the effect of collisions between charged and neutral particles in the probe sheath plays important role. Existingtheoretical models introducing collision corrections of the probe current are not experimentally verified in the full range of pressures and plasma densities and therefore not universally applicable. Suggested Langmuir probe measurements in the welldefined plasma of the UHV stationary and flowing afterglow systems will contribute to the understanding of the influence of collisions to the Langmuir probe electron and ion current collection in the pressure range up to approximately 1 kPa. The study ofthe plasma in the magnetic field is simplified in the experimental system of cylindrical magnetron. The homogeneous axial magnetic field is perpendicular to the radial electric field. Radial density profiles measured at 5 different axial positions showed (en)
  • Langmuirova sonda dovoluje při nízkých tlacích neutrálního plynu měřit parametry nízkoteplotního plazmatu s přijatelnou přesnosti. Při vyšších tlacích neutrálního plynu se však uplatňuje vliv srážek nabitých částic s neutrály ve vrstvě prostorovéhonáboje v okolí sondy. Dostupné teoretické modely pro zavedení srážkových korekcí zatím nejsou v potřebném rozsahu tlaků a koncentrací experimentálně prověřené a obecně aplikovatelné. Navrhovaná sondová měření v dobře definovaných podmínkách UHV aparaturypro studium dohasínajícího plazmatu ve stacionárním a proudícím prostředí (stationary/flowing afterglow) přispějí k objasnění vlivu srážek na sběr nabitých částic sondou při vyšších tlacích v rozsahu cca do 1 kPa. Experimentální systém stejnosměrnéhoválcového magnetronu přináší při studiu plazmatu v magnetickém poli zjednodušení v geometrické konfiguraci. Homogenní axiální magnetické pole je zde kolmé na radiální pole elektrické. Profil koncentrace plazmatu naměřený v několika diskrétních axiálních
Title
  • Probe diagnostic and simulation of the DC and afterglow discharge (en)
  • Sondová diagnostika a modelování stejnosměrného výboje a dohasínajícího plazmatu
skos:notation
  • GP202/01/D095
http://linked.open...avai/cep/aktivita
http://linked.open...kovaStatniPodpora
http://linked.open...ep/celkoveNaklady
http://linked.open...datumDodatniDoRIV
http://linked.open...i/cep/druhSouteze
http://linked.open...ep/duvernostUdaju
http://linked.open.../cep/fazeProjektu
http://linked.open...ai/cep/hlavniObor
http://linked.open...hodnoceniProjektu
http://linked.open...vai/cep/kategorie
http://linked.open.../cep/klicovaSlova
  • Neuvedeno. (en)
http://linked.open...ep/partnetrHlavni
http://linked.open...inujicichPrijemcu
http://linked.open...cep/pocetPrijemcu
http://linked.open...ocetSpoluPrijemcu
http://linked.open.../pocetVysledkuRIV
http://linked.open...enychVysledkuVRIV
http://linked.open...okUkonceniPodpory
http://linked.open...okZahajeniPodpory
http://linked.open...iciPoslednihoRoku
http://linked.open...atUdajeProjZameru
http://linked.open.../vavai/cep/soutez
http://linked.open...usZobrazovaneFaze
http://linked.open...ai/cep/typPojektu
http://linked.open.../cep/vedlejsiObor
http://linked.open...jektu+dodavatelem
  • V průběhu řešení grantového projektu byla prováděna sondová měření ve stejnosměrném doutnavém výboji na dvou válcových magnetronech, které se liší délkou výbojové komory. Podrobně byla studována axiální nehomogenita koncentrace nabitých částic pomocí axi (cs)
  • In frame of the project the Langmuir probe measurements were performed on two types of cylindrical magnetron systems with different length of the discharge volume. The study focused on the axial inhomogeneity of the plasma density using the probe movable (en)
http://linked.open...tniCyklusProjektu
is http://linked.open...vavai/riv/projekt of
is http://linked.open...vavai/cep/projekt of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software