Attributes | Values |
---|
rdf:type
| |
rdfs:seeAlso
| |
Description
| - This is a new and perspective trend of real time non-contact measurements of arbitrary shape deformation of surfaces. The principle of the method is based on measurement of the gradient of wave field after its interaction with the tested object. Thetechnique uses new array optical elements, CCD sensors and LC displays with a subsequent automatic computer evaluation. In comparison to optical measurement methods used at present, which do not allow to investigate arbitrary deformations and alsorequire laser as a source of radiation, this method has the advantage of measuring arbitrary deformations, the laser is not required as a source of radiation and it is possible to measure dynamic deformations. It is not possible with commonly usedmeasurement methods. Further purchase costs for the proposed measurement technique are much lower than costs of present interferometric systems. The proposed method can be used for a noncontact measurement of shape deformation of surfaces, e.g. for (en)
- Jedná se o nový a to velmi perspektivní směr bezkontaktního měření libovolných tvarových deformací ploch a to v reálném čase. Princip metody spočívá v měření gradientu vlnového pole po jeho interakci s měřeným objektem a to pomocí nových maticovýchoptických prvků, CCD senzoru a LCD prvků s následovným automatickým počítačovým vyhodnocením. Na rozdíl od stávajících optických metod (např. interferenčních metod), které neumožňují zjistit libovolné deformace a vyžadují laser jako zdroj záření, má tatometodatu výhodu, že umožňuje určit libovolně velké deformace měřeného objektu, nevyžaduje nutně laser jako zdroj záření a dále umožňuje i měření časově se rychle měnících deformací, což žádná ze stávajících metod neumožňuje. Dále též náklady na pořízenítakové hoto měřícího systému jsou několikanásobně nižší nežli u stávajících velmi robustních bezkontaktních měřících systémů. Navrhovanou metodu je možno použít pro bezkontaktní měření tvarových deformací ploch při testování konstrukčních prvků nebo
|
Title
| - Noncontact measurement of shape deformation of surfaces using sensor of wave field gradient (en)
- Bezkontaktní měření tvarových deformací ploch pomocí senzoru gradientu vlnového pole
|
skos:notation
| |
http://linked.open...avai/cep/aktivita
| |
http://linked.open...kovaStatniPodpora
| |
http://linked.open...ep/celkoveNaklady
| |
http://linked.open...datumDodatniDoRIV
| |
http://linked.open...i/cep/druhSouteze
| |
http://linked.open...ep/duvernostUdaju
| |
http://linked.open.../cep/fazeProjektu
| |
http://linked.open...ai/cep/hlavniObor
| |
http://linked.open...hodnoceniProjektu
| |
http://linked.open...vai/cep/kategorie
| |
http://linked.open.../cep/klicovaSlova
| |
http://linked.open...ep/partnetrHlavni
| |
http://linked.open...inujicichPrijemcu
| |
http://linked.open...cep/pocetPrijemcu
| |
http://linked.open...ocetSpoluPrijemcu
| |
http://linked.open.../pocetVysledkuRIV
| |
http://linked.open...enychVysledkuVRIV
| |
http://linked.open...okUkonceniPodpory
| |
http://linked.open...okZahajeniPodpory
| |
http://linked.open...iciPoslednihoRoku
| |
http://linked.open...atUdajeProjZameru
| |
http://linked.open.../vavai/cep/soutez
| |
http://linked.open...usZobrazovaneFaze
| |
http://linked.open...ai/cep/typPojektu
| |
http://linked.open.../cep/vedlejsiObor
| |
http://linked.open...jektu+dodavatelem
| - A laboratory measurement system was developed for experimental measurement of wave-front deformation using a gradient wave-front sensor. It was performed a detailed analysis of algorithms for wave-front retrieval with respect to measurement accuracy and (en)
- V rámci řešení projektu byl navržen a zkonstruován měřící systém pro laboratorní vyhodnocování tvaru vlnoplochy s užitím maticového gradientního senzoru. V oblasti vyhodnocovacích metod byla provedena analýza vhodných vyhodnocovacích algoritmů, které byl (cs)
|
http://linked.open...tniCyklusProjektu
| |
is http://linked.open...vavai/riv/projekt
of | |
is http://linked.open...vavai/cep/projekt
of | |