About: Návrh a optimalizace pulzních sekvenci s ultrakrátkým echо-časem pro spolehlivou detekci obsahu myelinu v lidském mozku pomocí MR zobrazování.     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Projekt, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • The aim of the project is to design and optimize an ultra-short echo-time pulse sequence for a direct measurement of the short-T2 signals arising from white matter of the brain. There are two main obstacles to a reliable detection of myelin sheaths: 1) their signal decays to zero in a few tens of microseconds; and 2) their signal is overwhelmed by the predominant long-T2 components from white matter of the brain. The unique feature of the pulse sequence design will be a calibration procedure correcting for eddy-current induced image distortions, based on the measurement of k-space trajectory during the gradient ramp-up. The complete removal of residual long-T2 components will be achieved by optimized dual echo acquisition and subtraction, which will selectively depict signal from the short-T2 components. Following the technical development, a pilot study including healthy and multiple sclerosis volunteers will be performed to demonstrate the capabilities of the newly developed methodology for the direct myelin measurement. (en)
  • Cílem projektu je návrh a optimalizace pulsní sekvence s ultrakrátkým echo-časem pro přímé měření signálů s krátkým T2 pocházejících z bílé hmoty mozkové. Pro spolehlivou detekci myelinových obalů je nutno překonat dvě hlavní překážky: 1) jejich signál klesá k nule během několika desítek mikrosekund; a 2) jejich signál je překryt převládajícími složkami s dlouhým T2 z bílé hmoty mozkové. Unikátní vlastností navržené pulsní sekvence bude kalibrační procedura korigující distorze obrazu způsobené vířivými proudy, založená na měření k-trajektorie během zapínání gradientu. Kompletního odstranění zbytkových komponent s dlouhým T2 bude dosaženo optimalizovanou akvizicí dvojího echa a jejich odečtením bude použito schéma komprimovaného snímání, čímž bude stanoven signál komponent s krátkým T2. V návaznosti na technický vývoj bude provedena pilotní studie zahrnující zdravé dobrovolníky a dobrovolníky s roztroušenou sklerózou, aby bylo možně nově vyvinutou metodiku ověřit.
Title
  • Návrh a optimalizace pulzních sekvenci s ultrakrátkým echо-časem pro spolehlivou detekci obsahu myelinu v lidském mozku pomocí MR zobrazování.
  • Design and optimization of ultra-short echo-time sequence for reliable detection of myelin content in the human brain by magnetic resonance imaging. (en)
skos:notation
  • GA15-12607S
http://linked.open...avai/cep/aktivita
http://linked.open...kovaStatniPodpora
http://linked.open...ep/celkoveNaklady
http://linked.open...datumDodatniDoRIV
http://linked.open...i/cep/druhSouteze
http://linked.open...ep/duvernostUdaju
http://linked.open.../cep/fazeProjektu
http://linked.open...ai/cep/hlavniObor
http://linked.open...vai/cep/kategorie
http://linked.open.../cep/klicovaSlova
  • magnetic resonance imaging; myelin imaging; ultrashort echo time; eddy current correction; background suppression; compressive sensing. (en)
http://linked.open...ep/partnetrHlavni
http://linked.open...inujicichPrijemcu
http://linked.open...cep/pocetPrijemcu
http://linked.open...ocetSpoluPrijemcu
http://linked.open.../pocetVysledkuRIV
http://linked.open...enychVysledkuVRIV
http://linked.open.../prideleniPodpory
http://linked.open...iciPoslednihoRoku
http://linked.open...atUdajeProjZameru
http://linked.open.../vavai/cep/soutez
http://linked.open...usZobrazovaneFaze
http://linked.open...ai/cep/typPojektu
http://linked.open...ep/ukonceniReseni
http://linked.open.../cep/vedlejsiObor
http://linked.open...ep/zahajeniReseni
http://linked.open...tniCyklusProjektu
http://linked.open.../cep/klicoveSlovo
  • magnetic resonance imaging
  • background suppression
  • eddy current correction
  • myelin imaging
  • ultrashort echo time
is http://linked.open...vavai/cep/projekt of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software