| - The issue of designing, operation and rehabilitation of sewer systems in localities with mining work has a number of specific features that do not occur in designing of sewer systems in other localities - subsidence related to radical changes in the hydraulic conditions compared to the original assumptions, changes in static action on sewerage structures, specific requirements for refurbishment methods, etc. The application of standard principles in designing and constructing of sewer systems may cause major problems in these localities, sometimes resulting in destruction of these structures. This is accompanied by operating problems, and if immediate steps fail to be taken, important elements of the sewerage systems may have to be put out of service, which represents sanitary risks. This is an issue of utmost importance for the pilot locality as well as a number of other localities where mining work continues or has ceased. Addressing of this issue requires a multidisciplinary approach (en)
- Problematika navrhování, provozu a rekonstrukcí stokových sítí v oblastech důlních činností má řadu specifických rysů, které se při řešení stokových sítí v jiných lokalitách nevyskytují - poklesy terénu spojené s výraznými změnami hydraulických poměrů oproti původním předpokladům, změny statického působení na objekty kanalizace, specifické požadavky na sanační postupy a další. Aplikace běžných zásad pro navrhování a provádění stokových systémů může vést v těchto oblastech k závažným poruchám a v důsledku až k destrukci těchto objektů. V návaznosti se projevují provozní problémy, které při absenci včasného zásahu mohou vést k vyřazení důležitých prvků kanalizačních soustav z provozu s následným hygienickým rizikem. Jedná se o problém mimořádného významu pro pilotní oblast i řadu dalších lokalit v oblastech s probíhající či ukončenou těžbou. K řešení je nezbytný multidisciplinární přístup s návazností na rozvoj územních celků, to vše s dopadem na fungování daných lokalit v širších souvislostech.
|
Title
| - Rehabilitation of sewerage system structures in undermined localities (en)
- Rehabilitace kanalizačních staveb na poddolovaném území
|
skos:notation
| |
http://linked.open...avai/cep/aktivita
| |
http://linked.open...kovaStatniPodpora
| |
http://linked.open...ep/celkoveNaklady
| |
http://linked.open...datumDodatniDoRIV
| |
http://linked.open...i/cep/druhSouteze
| |
http://linked.open...ep/duvernostUdaju
| |
http://linked.open.../cep/fazeProjektu
| |
http://linked.open...ai/cep/hlavniObor
| |
http://linked.open...hodnoceniProjektu
| |
http://linked.open...vai/cep/kategorie
| |
http://linked.open.../cep/klicovaSlova
| - sewerage networks; undermining area; operation; rehabilitation (en)
|
http://linked.open...ep/partnetrHlavni
| |
http://linked.open...inujicichPrijemcu
| |
http://linked.open...cep/pocetPrijemcu
| |
http://linked.open...ocetSpoluPrijemcu
| |
http://linked.open.../pocetVysledkuRIV
| |
http://linked.open...enychVysledkuVRIV
| |
http://linked.open...lneniVMinulemRoce
| |
http://linked.open.../prideleniPodpory
| |
http://linked.open...iciPoslednihoRoku
| |
http://linked.open...atUdajeProjZameru
| |
http://linked.open.../vavai/cep/soutez
| |
http://linked.open...usZobrazovaneFaze
| |
http://linked.open...ai/cep/typPojektu
| |
http://linked.open...ep/ukonceniReseni
| |
http://linked.open...ep/zahajeniReseni
| |
http://linked.open...jektu+dodavatelem
| - A standard approach to the designing, reconstructions, constructions or even modelling of a sewage network on an undermined territory does not provide satisfactory results. It is clear from the grant project that the pipe capacity is influenced by hydrau (en)
- Klasický přístup k návrhu, rekonstrukcím či výstavbě, ale i k modelování stokové sítě na poddolovaném území nevede k uspokojivým výsledkům. Z výsledků řešení grantového projektu je zřejmý vliv hydraulické drsnosti na kapacitu potrubí. Práce prokázaly nut (cs)
|
http://linked.open...tniCyklusProjektu
| |
http://linked.open.../cep/klicoveSlovo
| - operation
- undermining area
- sewerage networks
|